Thin CdTe detector in diagnostic x-ray spectroscopy

被引:48
作者
Miyajima, S [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
x-ray spectra; CdTe Schottky diode detector; tailing; carrier trapping; stripping method;
D O I
10.1118/1.1566388
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A CdTe Schottky diode detector of 1 mm thickness was employed in diagnostic x-ray spectroscopy. The detector response to monoenergetic photons was investigated with gamma rays from the calibration sources (Am-241 and Ba-133). As spectral distortion due to carrier trapping, known as tailing, was small in gamma-ray spectra, the effects of carrier trapping were not taken into account in the calculation of response functions. The distortion due to the transmission of primary x rays and the escape of secondary x rays (K-fluorescent x rays and Compton-scattered x rays) from the crystal was included in the calculated response functions. X-ray spectra corrected using the response functions were in good agreement with the reference spectra obtained with a high-purity germanium detector. The results indicated that correction for the distortion due to carrier trapping is not necessary when using a thin CdTe detector in diagnostic x-ray spectroscopy. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:771 / 777
页数:7
相关论文
共 19 条
[1]  
Berger MJ, 1999, ESTAR PSTAR ASTAR CO
[2]  
Castro E.D., 1984, PHYS MED BIOL, V29, P1117
[4]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[5]  
HIRAYAMA H, 2000, 20003 KEK INT
[6]  
Hubbell J. H., 1995, 5632 NISTIR
[7]   CADMIUM TELLURIDE DETECTORS WITH THERMOELECTRIC COOLING [J].
KHUSAINOV, AK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :335-340
[8]   Performance of a new schottky CdTe detector for hard X-ray spectroscopy [J].
Matsumoto, C ;
Takahashi, T ;
Takizawa, K ;
Ohno, R ;
Ozaki, T ;
Mori, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :428-432
[9]   CdZnTe detector in mammographic x-ray spectroscopy [J].
Miyajima, S ;
Imagawa, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22) :3959-3972
[10]   Extraction of mean free path of charge carriers in CdZnTe crystals from measured full-energy peaks [J].
Miyajima, S ;
Sakuragi, H ;
Matsumoto, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (03) :533-538