Extraction of mean free path of charge carriers in CdZnTe crystals from measured full-energy peaks

被引:18
作者
Miyajima, S
Sakuragi, H
Matsumoto, M
机构
[1] Osaka Univ, Grad Sch Med, Course Hlth Sci, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Fac Med, Sch Allied Hlth Sci, Suita, Osaka 5650871, Japan
关键词
CdZnTe detector; tailing; mean free path; Hecht equation; X-ray spectrometry;
D O I
10.1016/S0168-9002(01)02126-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The mean free path of electrons (lambda(e)) and holes in a CdZnTe crystal were extracted from measured gamma-ray spectra. First, distortion due to Gaussian broadening was unfolded from full-energy peaks in the gamma-ray spectra. As a result, only tailing was left in the unfolded peaks. Second, lambda(e) and lambda(h), were determined by fitting tailing of full-energy peaks in calculated response functions to that in the unfolded gamma-ray spectra. The response functions were calculated using EGS4 with the Hecht equation coded. 2.5 x 10(2) cm for lambda(e) and 5.0 x 10(-2) cm for lambda(h) were obtained in an electric field of 2500 V/cm: the mutau products were found to be 1.0 x 10(-1) cm(2)/V for electrons and 2.0 x 10(-5) cm(2)/V for holes. This method is reasonable to obtain lambda(e) and lambda(h), which are necessary to correct the distortion caused by tailing in X-ray spectra. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 32 条
[1]   Gamma spectrometric characterization of various CdTe and CdZnTe detectors [J].
Arlt, R ;
Gryshchuk, V ;
Sumah, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01) :127-137
[2]   MONTE-CARLO SIMULATION STUDIES OF DETECTORS USED IN THE MEASUREMENT OF DIAGNOSTIC-X-RAY SPECTRA [J].
CHEN, CS ;
DOI, K ;
VYBORNY, C ;
CHAN, HP ;
HOLJE, G .
MEDICAL PHYSICS, 1980, 7 (06) :627-635
[3]   Multichannel CdZnTe gamma ray spectrometer [J].
Doty, FP ;
Lingren, CL ;
Apotovsky, BA ;
Brunsch, J ;
Butler, JF ;
Collins, T ;
Conwell, RL ;
Friesenhahn, S ;
Gormley, J ;
Pi, B ;
Zhao, S ;
Augustine, FL ;
Bennett, BA ;
Cross, E ;
James, RB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :185-189
[4]   CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems [J].
Eisen, Y ;
Shor, A ;
Mardor, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01) :158-170
[6]  
FIORATTI MP, 1972, NUCL INSTRUM METHODS, V98, P131, DOI 10.1016/0029-554X(72)90435-1
[7]   CdTe and CdZnTe crystals for room temperature gamma-ray detectors [J].
Franc, J ;
Höschl, P ;
Belas, E ;
Grill, R ;
Hlídek, P ;
Moravec, P ;
Bok, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01) :146-151
[8]   Simulation of CdZnTe gamma-ray spectrometer response [J].
Glière, A ;
Rosaz, M ;
Verger, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3) :250-254
[9]   Signal generation in CdZnTe strip detectors [J].
Hamel, LA ;
Macri, JR ;
Doty, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1422-1426
[10]   VERY HIGH-RESOLUTION DETECTION OF GAMMA-RADIATION AT ROOM-TEMPERATURE USING P-I-N DETECTORS OF CDZNTE AND HGCDTE [J].
HAMILTON, WJ ;
RHIGER, DR ;
SEN, S ;
KALISHER, MH ;
JAMES, K ;
REID, CP ;
GERRISH, V ;
BACCASH, CO .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :989-992