Fast high-resolution T1 mapping of the human brain

被引:80
作者
Deichmann, R [1 ]
机构
[1] Inst Neurol, Wellcome Dept Imaging Neurosci, London WC1N 3BG, England
基金
英国惠康基金;
关键词
T-1; mapping; quantitative brain imaging; relaxometry; quantification; high resolution;
D O I
10.1002/mrm.20552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A sequence for the acquisition of high-resolution T, maps, based on magnetization-prepared multislice fast low-angle shot (FLASH) imaging, is presented. In contrast to similar methods, no saturation pulses are used, resulting in an increased dynamic range of the relaxation process. Furthermore, it is possible to acquire data during all relaxation delays because only slice-selective radiofrequency (RF) pulses are used for inversion and excitation. This allows for a reduction of the total acquisition time, or scanning with a reduced bandwidth, which improves the signal-to-noise ratio (SNR). The method generates quantitative T-1 maps with an in-plane resolution of 1 mm, slice thickness of 4 mm, and whole-brain coverage in a clinically acceptable imaging time of about 19s per slice. It is shown that the use of off-center RF pulses does not result in imperfect inversion or magnetization transfer (MT) effects. In addition, an improved fitting algorithm based on smoothed flip angle maps is presented and tested successfully. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 30 条
[1]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[2]   Imaging lung function using rapid dynamic acquisition of T1-maps during oxygen enhancement [J].
Arnold, JFT ;
Fidler, F ;
Wang, T ;
Pracht, ED ;
Schmidt, M ;
Jakob, PM .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (05) :246-253
[3]   Multimodal image coregistration and partitioning - A unified framework [J].
Ashburner, J ;
Friston, K .
NEUROIMAGE, 1997, 6 (03) :209-217
[4]  
Berry I, 1999, J MAGN RESON IMAGING, V9, P441, DOI 10.1002/(SICI)1522-2586(199903)9:3<441::AID-JMRI12>3.0.CO
[5]  
2-R
[6]   Rapid T1 mapping using multislice echo planar imaging [J].
Clare, S ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :630-634
[7]   QUANTIFICATION OF T1 VALUES BY SNAPSHOT-FLASH NMR IMAGING [J].
DEICHMANN, R ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (03) :608-612
[8]  
Deichmann R, 1999, MAGNET RESON MED, V42, P206, DOI 10.1002/(SICI)1522-2594(199907)42:1<206::AID-MRM28>3.0.CO
[9]  
2-Q
[10]   Optimisation of the 3D MDEFT sequence for anatomical brain imaging: Technical implications at 1.5 and 3 T [J].
Deichmann, R ;
Schwarzbauer, C ;
Turner, R .
NEUROIMAGE, 2004, 21 (02) :757-767