Confirmatory analysis of Trenbolone using accurate mass measurement with LC/TOF-MS

被引:17
作者
Blokland, M. H. [1 ]
Zoontjes, P. W. [1 ]
Sterk, S. S. [1 ]
Stephany, R. W. [1 ]
Zweigenbaum, J. [2 ]
van Ginkel, L. A. [1 ]
机构
[1] Natl Inst Publ Hlth & Environm RIVM, NL-3720 BA Bilthoven, Netherlands
[2] Agilent Technol, Wilmington, DE USA
关键词
accurate mass measurement; exact mass; time of Flight Mass Spectrometry; triple quadrupole mass spectrometry; confirmation;
D O I
10.1016/j.aca.2008.04.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of accurate mass measurement as a confirmation tool is examined on a TOF-MS and compared with confirmation using a triple quadrupole mass spectrometer (QqQ-MS). Confirmation of the identity of a substance using mass-spectrometric detection has been described. However, the use of accurate mass measurement for confirmatory analysis has not been taken into account. In this study, criteria for confirmation with accurate mass are proposed and feasibility is demonstrated. Mass accuracy better than 3 ppm of the quasi-molecular ion and a fragment and their relative ratios determined with LC/TOF-MS are compared to the criteria of two transition ions and their ratio of LC/QqQ-MS. The results show that these criteria can be met for Trenbolone in samples of bovine urine and that single MS accurate mass measurement is comparable to nominal mass MS/MS for confirmation. The increase in popularity and availability of LC/TOF-MS instruments and the ease, of which exact masses can be measured, make it important to formulate criteria for this type of instrumentation. It is shown in this study that accurate mass measurement can be used for confirmatory analysis. However, more experiments need to be conducted to demonstrate the applicability of accurate mass measurement in general for residue analysis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 13 条
[1]   Trends in the identification of organic residues and contaminants:: EC regulations under revision [J].
André, F ;
De Wasch, KKG ;
De Brabander, HF ;
Impens, SR ;
Stolker, LAM ;
van Ginkel, L ;
Stephany, RW ;
Schilt, R ;
Courtheyn, D ;
Bonnaire, Y ;
Fürst, P ;
Gowik, P ;
Kennedy, G ;
Kuhn, T ;
Moretain, JP ;
Sauer, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (08) :435-445
[2]  
[Anonymous], 2004, METHODOLOGY ACCURATE
[3]   Establishing the fitness for purpose of mass spectrometric methods [J].
Bethem, R ;
Boison, J ;
Gale, J ;
Heller, D ;
Lehotay, S ;
Loo, J ;
Musser, S ;
Price, P ;
Stein, S .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (05) :528-541
[4]  
BLOKLAND MH, 2005, 2 INT S REC ADV FOOD
[5]   Intercomparison study on accurate mass measurement of small molecules in mass spectrometry [J].
Bristow, AWT ;
Webb, KS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1086-1098
[6]   Substance identification: the weak link in analytical toxicology [J].
de Zeeuw, RA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 811 (01) :3-12
[7]   Comparison of different mass spectrometric techniques combined with liquid chromatography for confirmation of pesticides in environmental water based on the use of identification points [J].
Hernández, F ;
Ibáñez, M ;
Sancho, JV ;
Pozo, OJ .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4349-4357
[8]   Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques [J].
Nielen, M. W. F. ;
van Engelen, M. C. ;
Zuiderent, R. ;
Ramaker, R. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :122-129
[9]  
SPHON JA, 1978, J ASSOC OFF ANA CHEM, V61, P1247
[10]   On the risk of false positive identification using multiple ion monitoring in qualitative mass spectrometry: Large-scale intercomparisons with a comprehensive mass spectral library [J].
Stein, Stephen E. ;
Heller, David N. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (06) :823-835