Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger

被引:333
作者
Bogert, LWJ
van Lieshout, JJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Cardiovasc Res Inst, NL-1100 DE Amsterdam, Netherlands
关键词
D O I
10.1113/expphysiol.2005.030262
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In this paper we review recent developments in the methodology of non-invasive finger arterial pressure measurement and the information about arterial flow that can be obtained from it. Continuous measurement of finger pressure based on the volume-clamp method was introduced in the early 1980s both for research purposes and for clinical medicine. Finger pressure tracks intra-arterial pressure but the pressure waves may differ systematically both in shape and magnitude. Such bias can, at least partly, be circumvented by reconstruction of brachial pressure from finger pressure by using a general inverse anti-resonance model correcting for the difference in pressure waveforms and an individual forearm cuff calibration. The Modelflow method as implemented in the Finometer computes an aortic flow waveform from peripheral arterial pressure by simulating a non-linear three-element model of the aortic input impedance. The methodology tracks fast changes in stroke volume (SV) during various experimental protocols including postural stress and exercise. If absolute values are required, calibration against a gold standard is needed. Otherwise, Modelflow-measured SV is expressed as change from control with the same precision in tracking. Beat-to-beat information on arterial flow offers important and clinically relevant information on the circulation beyond what can be detected by arterial pressure.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 113 条
[21]  
GAUER OTTO H., 1965, HANDBOOK PHYSIOL, V3, P2409
[22]   Tidal volume, cardiac output and functional residual capacity determine end-tidal CO2 transient during standing up in humans [J].
Gisolf, J ;
Wilders, R ;
Immink, RV ;
van Lieshout, JJ ;
Karemaker, JM .
JOURNAL OF PHYSIOLOGY-LONDON, 2004, 554 (02) :579-590
[23]   Models of brachial to finger pulse wave distortion and pressure decrement [J].
Gizdulich, P ;
Prentza, A ;
Wesseling, KH .
CARDIOVASCULAR RESEARCH, 1997, 33 (03) :698-705
[24]   CONTINUOUS NONINVASIVE CARDIAC-OUTPUT AS ESTIMATED FROM THE PULSE CONTOUR CURVE [J].
GRATZ, I ;
KRAIDIN, J ;
JACOBI, AG ;
DECASTRO, NG ;
SPAGNA, P ;
LARIJANI, GE .
JOURNAL OF CLINICAL MONITORING, 1992, 8 (01) :20-27
[25]   Reconstruction of radial artery pressure from non-invasive finger arterial pressure measurements in patients with ischemic heart disease [J].
Guelen, I ;
Bogert, LWJ ;
van Beek, M ;
Westerhof, BE ;
van der Sar, GL ;
van Lieshout, JJ .
JOURNAL OF HYPERTENSION, 2004, 22 :S280-S281
[26]   Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure [J].
Guelen, I ;
Westerhof, BE ;
van der Sar, GL ;
van Montfrans, GA ;
Kiemeneij, F ;
Wesseling, KH ;
Bos, WJW .
BLOOD PRESSURE MONITORING, 2003, 8 (01) :27-30
[27]  
HALES S, 1733, STATICAL ESSAYS HAEM
[28]   COMPARISON OF THE FICK AND DYE INJECTION METHODS OF MEASURING THE CARDIAC OUTPUT IN MAN [J].
HAMILTON, WF ;
RILEY, RL ;
ATTYAH, AM ;
COURNAND, A ;
FOWELL, DM ;
HIMMELSTEIN, A ;
NOBLE, RP ;
REMINGTON, JW ;
RICHARDS, DW ;
WHEELER, NC ;
WITHAM, AC .
AMERICAN JOURNAL OF PHYSIOLOGY, 1948, 153 (02) :309-321
[29]   Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress [J].
Harms, MPM ;
Wesseling, KH ;
Pott, F ;
Jenstrup, M ;
von Goudoever, J ;
Secher, NH ;
van Lieshout, JJ .
CLINICAL SCIENCE, 1999, 97 (03) :291-301
[30]   Postural effects on cardiac output and mixed venous oxygen saturation in humans [J].
Harms, MPM ;
van Liesthout, JJ ;
Jenstrup, M ;
Pott, F ;
Secher, NH .
EXPERIMENTAL PHYSIOLOGY, 2003, 88 (05) :611-616