Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger

被引:333
作者
Bogert, LWJ
van Lieshout, JJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Cardiovasc Res Inst, NL-1100 DE Amsterdam, Netherlands
关键词
D O I
10.1113/expphysiol.2005.030262
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In this paper we review recent developments in the methodology of non-invasive finger arterial pressure measurement and the information about arterial flow that can be obtained from it. Continuous measurement of finger pressure based on the volume-clamp method was introduced in the early 1980s both for research purposes and for clinical medicine. Finger pressure tracks intra-arterial pressure but the pressure waves may differ systematically both in shape and magnitude. Such bias can, at least partly, be circumvented by reconstruction of brachial pressure from finger pressure by using a general inverse anti-resonance model correcting for the difference in pressure waveforms and an individual forearm cuff calibration. The Modelflow method as implemented in the Finometer computes an aortic flow waveform from peripheral arterial pressure by simulating a non-linear three-element model of the aortic input impedance. The methodology tracks fast changes in stroke volume (SV) during various experimental protocols including postural stress and exercise. If absolute values are required, calibration against a gold standard is needed. Otherwise, Modelflow-measured SV is expressed as change from control with the same precision in tracking. Beat-to-beat information on arterial flow offers important and clinically relevant information on the circulation beyond what can be detected by arterial pressure.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 113 条
[51]  
LANGEWOUTERS GJ, 1985, BIOMECHANICS CURRENT, P245
[52]   Respiratory measurements of cardiac output: from elegant idea to useful test [J].
Laszlo, G .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (02) :428-437
[53]   INFLUENCE OF AGE ON CARDIOVASCULAR AND RENAL RESPONSES TO TILTING [J].
LEE, TD ;
LINDEMAN, RD ;
YIENGST, MJ ;
SHOCK, NW .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (01) :55-&
[54]   Stroke volume monitored by modeling flow from finger arterial pressure waves mirrors blood volume withdrawn by phlebotomy [J].
Leonetti, P ;
Audat, F ;
Girard, A ;
Laude, D ;
Lefrère, F ;
Elghozi, JL .
CLINICAL AUTONOMIC RESEARCH, 2004, 14 (03) :176-181
[55]  
LUI K, 1982, AUST PAEDIATR J, V18, P32
[56]  
MAREY EJ, 1878, METHODE GRAPHIQUE SO
[57]   LEFT VENTRICULAR OUTPUT DERIVED FROM TIME-DERIVATIVE AND PHASE VELOCITIES OF AORTIC PRESSURE WAVE [J].
MCDONALD, DA ;
NICHOLS, WW .
MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (06) :678-690
[58]   A 30-year follow-up of the Dallas Bed rest and Training Study I. Effect of age on the cardiovascular response to exercise [J].
McGuire, DK ;
Levine, BD ;
Williamson, JW ;
Snell, PG ;
Blomqvist, CG ;
Saltin, B ;
Mitchell, JH .
CIRCULATION, 2001, 104 (12) :1350-1357
[59]   EVALUATION OF CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE DURING EXERCISE IN NORMAL SUBJECTS [J].
MOORE, R ;
SANSORES, R ;
GUIMOND, V ;
ABBOUD, R .
CHEST, 1992, 102 (02) :448-455
[60]   Use of pulse oximetry for blood pressure measurement after cardiac surgery [J].
Movius, AJ ;
Bratton, SL ;
Sorensen, GK .
ARCHIVES OF DISEASE IN CHILDHOOD, 1998, 78 (05) :457-460