Three-dimensional spiral technique for high-resolution functional MRI

被引:27
作者
Hu, Yanle
Glover, Gary H.
机构
[1] Stanford Univ, Lucas Ctr MR Spectroscopy & Imaging, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
关键词
high-resolution fMRI; 3D spiral method; SNR; BOLD contrast; volume excitation; fast imaging;
D O I
10.1002/mrm.21328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For high-resolution functional MRI (fMRI) studies, signal-to-noise ratio (SNR) plays an important role. Any method that results in an improvement in SNR will be able to improve the quality of activation maps. Three-dimensional (3D) acquisition methods in general can provide higher SNR than that of 2D methods due to volume excitation. To demonstrate the superiority of 3D methods for high-resolution fMRI scans, a comparison study between 3D and 2D spiral methods was performed using a contrast-reversing checkerboard visual stimulus. A 3-inch surface coil was used to limit the in-plane FOV to 14 cm x 14 cm so that 32 1-mm slices with an in-plane voxel size of 1.1 mm x 1.1 mm could be acquired within 5.76 seconds. Results showed that average numbers of activated voxels were 407 and 841 for 2D and 3D methods, respectively (P < 0.01). Therefore, the 3D technique may be a useful alternative to the conventional 2D method for high resolution fMRI studies.
引用
收藏
页码:947 / 951
页数:5
相关论文
共 30 条
[1]   High-resolution, multiple gradient-echo functional MRI at 1.5 T [J].
Barth, M ;
Reichenbach, JR ;
Venkatesan, R ;
Moser, E ;
Haacke, EM .
MAGNETIC RESONANCE IMAGING, 1999, 17 (03) :321-329
[2]   Mapping the MRI voxel volume in which thermal noise matches physiological noise-Implications for fMRI [J].
Bodurka, J. ;
Ye, F. ;
Petridou, N. ;
Murphy, K. ;
Bandettini, P. A. .
NEUROIMAGE, 2007, 34 (02) :542-549
[3]   High-resolution, spin-echo BOLD, and CBF AM at 4 and 7 T [J].
Duong, TQ ;
Yacoub, E ;
Adriany, G ;
Hu, XP ;
Ugurbil, K ;
Vaughan, JT ;
Merkle, H ;
Kim, SG .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :589-593
[4]   Retinotopic organization in human visual cortex and the spatial precision of functional MRI [J].
Engel, SA ;
Glover, GH ;
Wandell, BA .
CEREBRAL CORTEX, 1997, 7 (02) :181-192
[5]   FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION AT HIGH SPATIAL-RESOLUTION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :139-144
[6]   Self-navigated spiral fMRI: Interleaved versus single-shot [J].
Glover, GH ;
Lai, S .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) :361-368
[7]  
Glover GH, 1997, ISMRM FAST MRI WORKS, P115
[8]   The fusiform face area subserves face perception, not generic within-category identification [J].
Grill-Spector, K ;
Knouf, N ;
Kanwisher, N .
NATURE NEUROSCIENCE, 2004, 7 (05) :555-562
[9]   High-resolution imaging reveals highly selective nonface clusters in the fusiform face area [J].
Grill-Spector, Kalanit ;
Sayres, Rory ;
Ress, David .
NATURE NEUROSCIENCE, 2006, 9 (09) :1177-1185
[10]   High-resolution segmented EPI in a motor task fMRI study [J].
Hoogenraad, FGC ;
Pouwels, PJW ;
Hofman, MBM ;
Rombouts, SARB ;
Lavini, C ;
Leach, MO ;
Haacke, EM .
MAGNETIC RESONANCE IMAGING, 2000, 18 (04) :405-409