Implementation of multicommutation principle with flow-through multioptosensors

被引:21
作者
Llorent-Martínez, EJ
Domínguez-Vidal, A
Ortega-Barrales, P
de la Guardia, M
Molina-Díaz, A
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, E-23071 Jaen, Spain
[2] Univ Valencia, Dept Analyt Chem, Burjassot 46100, Spain
关键词
multicommutation; pharmaceuticals; flow-through optosensor;
D O I
10.1016/j.aca.2005.04.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, the combination of multicommutation concept with flow-through multioptosensors is exploited and a biparameter multicommutated UV sensor is developed. A very easy-operated and automated sensing device is proposed here and demonstrated to be useful in the routine analysis by applying it to the determination of two widely used pharmaceuticals chosen as model analytes: salicylamide and caffeine. The particulated solid phase used performs two functions: (a) states selectivity conditions by itself in the flow cell and (b) provides appropriate separation of the analytes in the on-line precolumn, thus making possible the sequential arrival of the analytes to the detection zone. Both carrier and eluting solutions chosen allow (with a very simple solenoid valve configuration and operation) the transitory signals to be developed in a completely automated device. Drastic reduction of carrier and eluting solutions used are achieved as compared to typically FIA optosensor configuration. The sensor responds linearly in the range 2-30 and 1-14 mu g ml(-1) for SLC and CF, with detection limits of 0.33 and 0. 15 mu g ml(-1), respectively. Solution savings between 50 and 85% were obtained when comparing to typical flow injection analysis (FIA). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 18 条
[1]   SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .3. SIMULTANEOUS DETERMINATION OF CR(VI) IN 2 CONCENTRATION RANGES [J].
ALONSOCHAMARRO, J ;
BARTROLI, J ;
BARBER, R .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :219-223
[2]   A selective optosensor for UV spectrophotometric determination of thiamine in the presence of other vitamins B [J].
Barrales, PO ;
de Córdova, MLF ;
Díaz, AM .
ANALYTICA CHIMICA ACTA, 1998, 376 (02) :227-233
[3]   Simultaneous determination of thiamine and pyridoxine in pharmaceuticals by using a single flow-through biparameter sensor [J].
Barrales, PO ;
Vidal, AD ;
de Córdova, MLF ;
Díaz, AM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (3-4) :619-630
[4]   MERGING ZONES IN FLOW INJECTION ANALYSIS .1. DOUBLE PROPORTIONAL INJECTOR AND REAGENT CONSUMPTION [J].
BERGAMIN, H ;
ZAGATTO, EAG ;
KRUG, FJ ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :17-23
[5]   Fast flow-injection fluorimetric determination of amiloride by using a solid sensing zone [J].
Domínguez-Vidal, A ;
Ortega-Barrales, P ;
Molina-Díaz, A .
TALANTA, 2002, 56 (06) :1005-1013
[6]   Terbium-sensitized luminescence optosensor for the determination of norfloxacin in biological fluids [J].
Martínez, EJL ;
Reyes, JFG ;
Barrales, PO ;
Díaz, AM .
ANALYTICA CHIMICA ACTA, 2005, 532 (02) :159-164
[7]   FULLY AUTOMATED-SYSTEM FOR THE CONTINUOUS MONITORING OF AMMONIUM ION IN FISH FARMING PLANT SEA-WATER BY FLOW-INJECTION ANALYSIS [J].
MURAKI, H ;
HIGUCHI, K ;
SASAKI, M ;
KORENAGA, T ;
TOEI, K .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :345-349
[8]   Microdetermination of vitamin B1 in the presence of vitamins B2, B6, and B12 by solid-phase UV spectrophotometry [J].
Ortega-Barrales, P ;
Córdova, MLF ;
Molina-Díaz, A .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :271-275
[9]   Solid phase Fourier transform near infrared spectroscopy [J].
Ortega-Barrales, P ;
Ayora-Cañada, MJ ;
Molina-Díaz, A ;
Garrigues, S ;
de la Guardia, M .
ANALYST, 1999, 124 (04) :579-582
[10]   OPERATOR-FREE FLOW-INJECTION ANALYZER [J].
PASQUINI, C ;
DEFARIA, LC .
JOURNAL OF AUTOMATIC CHEMISTRY, 1991, 13 (04) :143-146