Optimized gating scheme for rapid lifetime determinations of single-exponential luminescence lifetimes

被引:55
作者
Chan, SP
Fuller, ZJ
Demas, JN [1 ]
DeGraff, BA
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[2] James Madison Univ, Dept Chem, Harrisonburg, VA 22807 USA
关键词
D O I
10.1021/ac0102361
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rapid lifetime method (RLD) for determining excited-state lifetimes uses the ratio of the areas under two regions of the decay. To get good precision with the standard method, prior knowledge of the lifetime is essential to selecting the integration regions. As will be shown, the usual method of selecting integration regions is far from optimal. An optimal gating scheme that is more precise and much more forgiving in the selection of integration region than any of the prior methods will be shown. Monte Carlo simulations were performed to determine the optimal gating. Experimental data was used to confirm the capabilities of the optimized RLD. The speed of the optimal RLD is similar to the standard RLD but without the necessity of matching the integration interval to the lifetime for precise results.
引用
收藏
页码:4486 / 4490
页数:5
相关论文
共 11 条
[1]  
Ashworth H A, 1983, UNPUB
[2]   AN ERROR ANALYSIS OF THE RAPID LIFETIME DETERMINATION METHOD FOR THE EVALUATION OF SINGLE EXPONENTIAL DECAYS [J].
BALLEW, RM ;
DEMAS, JN .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :30-33
[3]  
GLOVERFISCHER D, 1994, THESIS U VIRGINIA
[4]  
Lakowicz J. R., 2010, PRINCIPLES FLUORESCE
[5]   CHIRAL DISCRIMINATION IN ELECTRONIC ENERGY-TRANSFER PROCESSES BETWEEN DISSYMMETRIC METAL-COMPLEXES IN SOLUTION - TIME-RESOLVED CHIROPTICAL LUMINESCENCE MEASUREMENTS OF ENANTIOSELECTIVE EXCITED-STATE QUENCHING KINETICS [J].
METCALF, DH ;
SNYDER, SW ;
DEMAS, JN ;
RICHARDSON, FS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (15) :5681-5695
[6]   FUEL EQUIVALENCE RATIO IMAGING FOR METHANE JETS [J].
NI, TQ ;
MELTON, LA .
APPLIED SPECTROSCOPY, 1993, 47 (06) :773-781
[7]   Error analysis of the rapid lifetime determination method for double-exponential decays and new windowing schemes [J].
Sharman, KK ;
Periasamy, A ;
Ashworth, H ;
Demas, JN ;
Snow, NH .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :947-952
[8]   BIAS AND PRECISION IN THE ESTIMATION OF EXPONENTIAL DECAY PARAMETERS FROM SPARSE DATA [J].
TELLINGHUISEN, J ;
WILKERSON, CW .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1240-1246
[9]   A 2-DIMENSIONAL FLUORESCENCE LIFETIME IMAGING-SYSTEM USING A GATED IMAGE INTENSIFIER [J].
WANG, XF ;
UCHIDA, T ;
COLEMAN, DM ;
MINAMI, S .
APPLIED SPECTROSCOPY, 1991, 45 (03) :360-366
[10]  
WATERS PD, 1992, APPL SPECTROSC, V47, P111