Simultaneous noninvasive measurement of blood flow in the great cardiac vein and left anterior descending artery

被引:6
作者
Bedaux, WLF [1 ]
Hofman, MBM
Visser, CA
van Rossum, AC
机构
[1] Vrije Univ Amsterdam, Univ Hosp, Dept Cardiol, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Univ Hosp, Dept Clin Phys & Informat, Amsterdam, Netherlands
[3] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[4] Vrije Univ Amsterdam, Inst Cardiovasc Res, Amsterdam, Netherlands
关键词
coronary vessels; flow dynamics; magnetic resonance imaging; velocity quantification;
D O I
10.1081/JCMR-100107471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance (MR) flow mapping can be used to quantify flow velocity and volume flow in the coronary vessels noninvasively. The close anatomic relationship of the left anterior descending artery (LAD) with the great cardiac vein (GCV) allows imaging of both in one view. We examined the feasibility to discriminate between these two vessels based on the flow pattern and to measure the flow quantitatively. Eleven individuals with a normal LAD and 8 patients with a diseased LAD underwent MR imaging. From MR angiograms using connectivity to the aortic root, differentiation between the LAD and GCV was obtained. Perpendicular to both vessels, phase-contrast velocity mapping was performed to measure phasic and mean volume flow. After correction for cardiac motion of the vessel, GCV flow was found to be mainly systolic and pointing in the inverse direction as the predominantly diastolic flow in the LAD. These criteria appeared valid in all subjects, even in cases of highly stenotic arteries. The volume flow measurements corrected for body surface area were 31 +/- 15 ml/min/m(2) in the normal LAD (n = 11) and 21 +/- 10 ml/min/m(2) in the diseased LAD (n = 7). The volume flow measurements in the GCV corrected for body surface area were 23 +/- 19 ml/min/m(2) in the normal vessels and 19 +/- 16 ml/min/m(2) in the diseased vessels. In the patient with an occluded LAD and collaterals, the volume flow in the GCV was 7 ml/min/m(2). MR is a unique tool for noninvasive simultaneous measurement of the flow pattern and volume flow in the GCV and the LAD, showing a clear distinction between arterial and venous flow.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 27 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   PHASIC VOLUMETRIC CORONARY VENOUS OUTFLOW PATTERNS IN CONSCIOUS DOGS [J].
CANTY, JM ;
BROOKS, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (05) :H1457-H1463
[3]   Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames [J].
Clarke, GD ;
Hundley, WG ;
McColl, RW ;
Eckels, R ;
Smith, D ;
Chaney, C ;
Li, HF ;
Peshock, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :733-742
[4]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[5]   PRESSURE-FLOW CHARACTERISTICS AND NUTRITIONAL CAPACITY OF CORONARY VEINS IN DOGS [J].
COHEN, MV ;
MATSUKI, T ;
DOWNEY, JM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (04) :H834-H846
[6]   SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS [J].
CONTURO, TE ;
SMITH, GD .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :420-437
[7]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[8]   REGIONAL CORONARY VENOUS FLOW RESPONSES TO TRANSIENT CORONARY-ARTERY OCCLUSION IN HUMAN-BEINGS [J].
FELDMAN, RL ;
CONTI, CR ;
PEPINE, CJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (01) :1-10
[9]   EVALUATION OF CORONARY COLLATERAL CIRCULATION IN CONSCIOUS HUMANS [J].
FELDMAN, RL ;
PEPINE, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (09) :1233-1236
[10]   Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification [J].
Hofman, MBM ;
Wickline, SA ;
Lorenz, CH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :568-576