Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames

被引:23
作者
Clarke, GD [1 ]
Hundley, WG [1 ]
McColl, RW [1 ]
Eckels, R [1 ]
Smith, D [1 ]
Chaney, C [1 ]
Li, HF [1 ]
Peshock, RM [1 ]
机构
[1] UNIV TEXAS,SW MED CTR,DEPT INTERNAL MED,DALLAS,TX 75235
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 05期
关键词
phase-contrast MRI; cine MRI; coronary artery flow; breath-hold MRI;
D O I
10.1002/jmri.1880060506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phase-contrast magnetic resonance imaging (PC-MRI) can be used to produce multiframe cine now images of the coronary arteries. Accurate coronary flow measurement requires the elimination of respiratory motion artifacts using k-space segmentation to acquire the data in a single breath-hold, However, the duration of the breath-hold is proportional to the number of cine frames, In the present study, the number of cine frames was varied and the accuracies of the coronary now measurements were assessed using perivascular US. For the range of flows studied (2 ml/min to 147 ml/min), the correlation coefficients for PC-MRI and US increased (.70-.98) and the limits of agreement improved (+/-45 ml . min(-1) to +/-10 ml . min(-1)) as the number of cine frames increased from one to six. The results suggest that the accuracy of breath-hold cine PC-MRI measurements of coronary artery now improves as the number of cine frames increases.
引用
收藏
页码:733 / 742
页数:10
相关论文
共 42 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1157-1166
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   IS CORONARY PLOW RESERVE IN RESPONSE TO PAPAVERINE REALLY NORMAL IN SYNDROME-X [J].
CHAUHAN, A ;
MULLINS, PA ;
PETCH, MC ;
SCHOFIELD, PM .
CIRCULATION, 1994, 89 (05) :1998-2004
[5]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[6]   EARLY DETECTION OF ABNORMAL CORONARY FLOW RESERVE IN ASYMPTOMATIC MEN AT HIGH-RISK FOR CORONARY-ARTERY DISEASE USING POSITRON EMISSION TOMOGRAPHY [J].
DAYANIKLI, F ;
GRAMBOW, D ;
MUZIK, O ;
MOSCA, L ;
RUBENFIRE, M ;
SCHWAIGER, M .
CIRCULATION, 1994, 90 (02) :808-817
[7]   SLOPE OF THE INSTANTANEOUS HYPEREMIC DIASTOLIC CORONARY FLOW VELOCITY-PRESSURE RELATION - A NEW INDEX FOR ASSESSMENT OF THE PHYSIOLOGICAL SIGNIFICANCE OF CORONARY STENOSIS IN HUMANS [J].
DIMARIO, C ;
KRAMS, R ;
GIL, R ;
SERRUYS, PW .
CIRCULATION, 1994, 90 (03) :1215-1224
[8]   Assessing the Hemodynamic Significance of Coronary Artery Stenoses: Analysis of Translesional Pressure-Flow Velocity Relations in Patients [J].
Donohue, Thomas J. ;
Kern, Morton J. ;
Aguirre, Frank V. ;
Bach, Richard G. ;
Wolford, Thomas ;
Bell, Calvin A. ;
Segal, Jerome .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :449-458
[9]   SIMULTANEOUS DETECTION OF MULTIPLE COMPONENTS OF MOTION WITH MRI [J].
DUMOULIN, CL ;
DARROW, RD ;
EISNER, DR ;
TARNAWSKI, M ;
SCOTT, KT ;
CARO, CG .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :652-660
[10]   FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
GERVINO, E ;
LI, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :699-703