Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever

被引:52
作者
Campbell, GA [1 ]
Mutharasan, R [1 ]
机构
[1] Drexel Univ, Dept Chem Engn, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
cantilevers; resonance; added mass; evaporation; sensitivity;
D O I
10.1016/j.sna.2005.05.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Composite resonant millimeter-sized piezoelectric cantilevers were fabricated and their mass change sensitivity was evaluated using liquid evaporation experiments. The cantilever sensor was immersed to 1 mm depth in two volatile fluids, and one non-volatile fluid. Deionized water and 50% ethanol-water solution showed a resonant frequency change of 19 +/- 1 and 23 +/- 1 Hz/min, respectively. The cantilever liquid level change sensitivity (phi) was determined as 0.26 +/- 0.0 1 mu m/Hz. Experimental measurement of liquid level change of deionized water at room temperature and humidity was found to be 5.0 +/- 0.1 mu m/min, and is in good agreement with first principles model prediction of 5.5 mu m/min. We have modeled the added mass effects as proportional to displaced liquid mass. Such a model agrees with experimental results for immersion depths of less than 1 mm. The model provides a method for determining cantilever's spring constant and the added mass coefficient. The significance of the results we report is that millimeter-sized piezoelectric-actuated cantilevers have the sensitivity for measuring micron-level liquid level changes. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:326 / 334
页数:9
相关论文
共 35 条
[1]  
BATES KS, 1993, US PATIENT, V5, P251
[2]  
CAMPBELL GA, IN PRESS BIOSENS BIO
[3]  
CHERN EJ, 1990, MATER EVAL, V48, P481
[4]   Low-frequency acoustic resonance level detector with neural-network classification [J].
Donlagic, D ;
Zavrsnik, M ;
Donlagic, D .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 55 (2-3) :99-106
[5]   Eigenfrequencies of a rectangular atomic force microscope cantilever in a medium [J].
Elmer, FJ ;
Dreier, M .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (12) :7709-7714
[6]  
FOGLER HS, 1999, ELEMENTS CHEM REACTI, P700
[7]   Sharpening contact resonance spectra in UAFM using Q-control [J].
Fukuda, K ;
Irihama, H ;
Tsuji, T ;
Nakamoto, K ;
Yamanaka, K .
SURFACE SCIENCE, 2003, 532 :1145-1151
[8]   Design and operation of a fiber optic sensor for liquid level detection [J].
Golnabi, H .
OPTICS AND LASERS IN ENGINEERING, 2004, 41 (05) :801-812
[9]   Evanescent sensing of biomolecules and cells [J].
Haddock, HS ;
Shankar, PM ;
Mutharasan, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (01) :67-74
[10]   LIQUID-LEVEL SENSOR WITH OPTICAL FIBERS [J].
IWAMOTO, K ;
KAMATA, I .
APPLIED OPTICS, 1992, 31 (01) :51-54