Influence of marrow on ultrasonic velocity and attenuation in bovine trabecular bone

被引:51
作者
Alves, JM
Ryaby, JT
Kaufman, JJ
Magee, FP
Siffert, RS
机构
[1] CUNY MT SINAI SCH MED,DEPT ORTHOPAED,NEW YORK,NY 10029
[2] ORTHOLOG CORP,PHOENIX,AZ 85034
[3] CYBERLOG INC,NEW YORK,NY 10012
[4] UNIV SAO PAULO,SCH ENGN SAO CARLOS,DEPT MAT ENGN,SAO CARLOS,SP,BRAZIL
关键词
osteoporosis; ultrasonic assessment; specific differential attenuation; ultrasonic velocity; broadband ultrasound attenuation;
D O I
10.1007/BF02509386
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurements of ultrasonic velocity and specific differential attenuation (SDA) were obtained on 24 bovine trabecular bone specimens from the femoral condyles. The measurements were obtained using two pairs of ultrasonic transducers, one with a low nominal center frequency (500 kHz) and the other pair with a high nominal center frequency (1 MHz). The ultrasonic velocity and specific differential attenuation associated with the bone samples were determined both with and without marrow, i.e., replacing the marrow with water in the pores of the trabecular bone. Significant increases (2.1% and 2.9%) in the velocity of ultrasound were observed after removal of the marrow, for the low and high frequency transducer pairs, respectively. In contrast, significant decreases (-6.5% and -8.8%) in SDA were observed after removal of the marrow, for the low and high frequency transducer pairs, respectively. The bone densities (BD) of the samples were also determined using single photon absorptiometry (SPA). Correlations between ultrasonic parameters and bone densities for samples both with and without marrow were found to be similar. For example, for the 1 MHz transducer pair, the correlation between BD and velocity was r = 0.86 with marrow, and r = 0.89 without marrow. This study also compared the results obtained using a contact (no water bath) technique and an insertion (with a water bath) technique of ultrasonic measurements. For the high frequency transducer pair, the correlation coefficients between the two methods were r = 0.99 and r = 0.93, for the velocity and specific differential attenuation, respectively. Similar results were found for the low frequency transducer pair as well. In addition, approximately equal correlations between BD and ultrasonic velocity and SDA were also found, indicating that contact and insertion measurements provide essentially equivalent information.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 33 条
[21]   INVITRO COMPARISON OF QUANTITATIVE COMPUTED-TOMOGRAPHY AND BROAD-BAND ULTRASONIC-ATTENUATION OF TRABECULAR BONE [J].
MCKELVIE, ML ;
FORDHAM, J ;
CLIFFORD, C ;
PALMER, SB .
BONE, 1989, 10 (02) :101-104
[22]   SPINE AND FEMUR DENSITY AND BROAD-BAND ULTRASOUND ATTENUATION OF THE CALCANEUS IN NORMAL SPANISH WOMEN [J].
PALACIOS, S ;
MENENDEZ, C ;
CALDERON, J ;
RUBIO, S .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (02) :99-102
[23]  
ROUX C, 1993, REV RHUMATISME ENGL, V12, P771
[24]   COMPARISON OF BROAD-BAND ULTRASOUND ATTENUATION TO SINGLE X-RAY ABSORPTIOMETRY MEASUREMENTS AT THE CALCANEUS IN POSTMENOPAUSAL WOMEN [J].
SALAMONE, LM ;
KRALL, EA ;
HARRIS, S ;
DAWSONHUGHES, B .
CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) :87-90
[25]   DEPENDENCE OF THE VELOCITY AND ATTENUATION OF ULTRASOUND IN BONE ON THE MINERAL-CONTENT [J].
TAVAKOLI, MB ;
EVANS, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (11) :1529-1537
[26]   THE EFFECT OF BONE-STRUCTURE ON ULTRASONIC-ATTENUATION AND VELOCITY [J].
TAVAKOLI, MB ;
EVANS, JA .
ULTRASONICS, 1992, 30 (06) :389-395
[27]  
VANDAELE PLA, 1994, J BONE MINER RES, V9, P1751
[28]   THE RELATIONSHIP BETWEEN ULTRASOUND AND DENSITOMETRIC MEASUREMENTS OF BONE MASS AT THE CALCANEUS IN WOMEN [J].
WAUD, CE ;
LEW, R ;
BARAN, DT .
CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (06) :415-418
[29]  
WELLS PNT, 1969, PHYSICAL PRINCIPLESJ
[30]   ULTRASONIC WAVE-PROPAGATION IN CANCELLOUS AND CORTICAL BONE - PREDICTION OF SOME EXPERIMENTAL RESULTS BY BIOT THEORY [J].
WILLIAMS, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (02) :1106-1112