Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation

被引:320
作者
Lubinski, MA [1 ]
Emelianov, SY
O'Donnell, M
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.741427
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In ultrasound elasticity imaging, strain decorrelation is a major source of error in displacements estimated using correlation techniques. This error can be significantly decreased by reducing the correlation kernel. Additional gains in signal-to-noise ratio (SNR) are possible by filtering the correlation functions prior to displacement estimation. Tradeoffs between spatial resolution and estimate variance are discussed, and estimation in elasticity imaging is compared to traditional time-delay estimation. Simulations and experiments on gel-based phantoms are presented. The results demonstrate that high resolution, high SNR strain estimates can be computed using small correlation kernels (on the order of the autocorrelation width of the ultrasound signal) and correlation filtering.
引用
收藏
页码:82 / 96
页数:15
相关论文
共 36 条
[11]   An elasticity microscope .1. Methods [J].
Cohn, NA ;
Emelianov, SY ;
Lubinski, MA ;
ODonnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1304-1319
[12]   All elasticity microscope .2. Experimental results [J].
Cohn, NA ;
Emelianov, SY ;
ODonnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1320-1331
[13]  
COHN NA, 1996, P IEEE ULTR S, P1143
[14]  
Erkamp R., 1997, ULTRASONIC IMAGING, V19, P60
[15]   Measuring the elastic modulus of small tissue samples [J].
Erkamp, RQ ;
Wiggins, P ;
Skovoroda, AR ;
Emelianov, SY ;
O'Donnell, M .
ULTRASONIC IMAGING, 1998, 20 (01) :17-28
[16]  
HALL TJ, 1996, P IEEE ULTR S, P1193
[17]   ESTIMATION OF LOCATION AND MOTION PARAMETERS OF A MOVING SOURCE OBSERVED FROM A LINEAR-ARRAY [J].
HASSAB, JC ;
GUIMOND, BW ;
NARDONE, SC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 70 (04) :1054-1061
[18]   ESTIMATION OF TIME-DELAY IN PRESENCE OF SOURCE OR RECEIVER MOTION [J].
KNAPP, CH ;
CARTER, GC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1977, 61 (06) :1545-1549
[19]   GENERALIZED CORRELATION METHOD FOR ESTIMATION OF TIME-DELAY [J].
KNAPP, CH ;
CARTER, GC .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1976, 24 (04) :320-327
[20]   AN AXIAL VELOCITY ESTIMATOR FOR ULTRASOUND BLOOD-FLOW IMAGING, BASED ON A FULL EVALUATION OF THE DOPPLER EQUATION BY MEANS OF A 2-DIMENSIONAL AUTOCORRELATION APPROACH [J].
LOUPAS, T ;
POWERS, JT ;
GILL, RW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (04) :672-688