Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: Impact and automated quality control

被引:10
作者
Chen, J
Galt, JR
Case, JA
Ye, JH
Cullom, SJ
Durbin, MK
Shao, L
Garcia, EV
机构
[1] Emory Univ, Dept Radiol, Atlanta, GA 30322 USA
[2] Cardiovasc Imaging Technol, Kansas City, MO USA
[3] Philips Med Syst, Milpitas, CA USA
关键词
single photon emission computed tomography; small field-of-view systems; attenuation correction; automated transmission scan truncation quality control;
D O I
10.1016/j.nuclcard.2005.04.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Small-field-of-view (FOV) dedicated cardiac single photon emission computed tomography (SPECT) systems will frequently exhibit severe transmission scan truncation that may degrade attenuation correction (AC). This study evaluated the impact of transmission scan truncation on AC and developed automated transmission scan truncation quality control (ATSTQC) for small-FOV systems. Methods and Results. Small-FOV data were simulated from the data of 10 patients acquired by a full-FOV Philips Vertex system. AC images of the full- and small-FOV data were compared by mean and maximum absolute differences of myocardial counts, and differences in stress and rest severity scores were calculated by use of the Emory Cardiac Toolbox.small-FOV systems. ATSTQC was developed to identify critical truncation that significantly increased these indices and then tested with 18 independent patients. Left-side truncation resulted in significant distortion of the quantitative indices. ATSTQC, developed on the condition that left-side truncation is critical, showed high concordance with the qualitative assessment in identification of critical truncation. Conclusions. Identification of left-side truncation as critical truncation is necessary to judge whether accurate AC can be obtained. The developed ATSTQC can accurately detect critical truncation and will help clinicians decide whether to use AC in a particular study.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 26 条
[11]  
GREGORIOU GK, 1994, J NUCL MED, V35, pP4
[12]   Quantitative Tc-99m attenuation-corrected sestamibi SPECT: Development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population [J].
Grossman, GB ;
Garcia, EV ;
Bateman, TM ;
Heller, GV ;
Johnson, LL ;
Folks, RD ;
Cullom, SJ ;
Galt, JR ;
Case, JA ;
Santana, CA ;
Halkar, RK .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) :263-272
[13]   The design and performance of a simultaneous transmission and emission tomography system [J].
Gullberg, GT ;
Morgan, HT ;
Zeng, GSL ;
Christian, PE ;
Di Bella, EVR ;
Tung, CH ;
Maniawski, PJ ;
Hsieh, YL ;
Datz, FL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1676-1698
[14]   Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging [J].
Hendel, RC ;
Berman, DS ;
Cullom, SJ ;
Follansbee, W ;
Heller, GV ;
Kiat, H ;
Groch, MW ;
Mahmarian, JJ .
CIRCULATION, 1999, 99 (21) :2742-2749
[15]   The value and practice of attenuation correction for myocardial perfusion SPECT imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine [J].
Hendel, RC ;
Corbett, JR ;
Cullom, SJ ;
DePuey, EG ;
Garcia, EV ;
Bateman, TM .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (01) :135-143
[16]   ATTENUATION COMPENSATION FOR CARDIAC SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING .1. IMPACT OF ATTENUATION AND METHODS OF ESTIMATING ATTENUATION MAPS [J].
KING, MA ;
TSUI, BMW ;
PAN, TS .
JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (06) :513-524
[17]   Comparison of three applications of ConTraSPECT [J].
Laurette, I ;
Clackdoyle, R ;
Welch, A ;
Natterer, F ;
Gullberg, GT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :2146-2153
[18]   Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: A multicenter trial [J].
Links, JM ;
Becker, LC ;
Rigo, P ;
Taillefer, R ;
Hanelin, L ;
Anstett, F ;
Burckhardt, D ;
Mixon, L .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (05) :414-425
[19]   Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT [J].
Links, JM ;
DePuey, EG ;
Taillefer, R ;
Becker, LC .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (02) :183-187
[20]  
LIU L, 1996, J NUCL MED, V37, P210