Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays

被引:167
作者
Dodge, A [1 ]
Fluri, K [1 ]
Verpoorte, E [1 ]
de Rooij, NF [1 ]
机构
[1] Univ Neuchatel, Inst Microtechnol, Sensors Actuators & Microsyst Lab, CH-2007 Neuchatel, Switzerland
关键词
D O I
10.1021/ac0015366
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents the first example of a microfluidic chip for heterogeneous bioassays using a locally immobilized biospecific layer and operated electrokinetically. The reaction chamber has picoliter dimensions and is integrated into a network of microchannels etched in glass. The high affinity of protein A (PA) for rabbit immunoglobulin G (rIgG) was exploited for chip testing, with PA being immobilized on microchannel walls and fluorescently labeled (Cy5) rIgG sewing as sample. It was possible to operate the chip in an immunoaffinity chromatographic manner, using electrokinetically pumped solutions. Concentration of antibody from dilute solution onto the solid phase was demonstrated, with signal gains of similar to 30 possible. A dose-response curve for Cy5-rIgG was obtained for concentrations down to 50 nM, for an incubation time of 200 s. The flexibility of chip layout was demonstrated for competitive immunoassay of rIgG using both a combined sample/tracer incubation and sequential addition of these solutions, With assay times generally below 5 min for this unoptimized device, the microfluidic approach described shows great potential for many high-throughput screening applications,
引用
收藏
页码:3400 / 3409
页数:10
相关论文
共 41 条
[31]   FLOW-INJECTION RENEWABLE SURFACE IMMUNOASSAY - A NEW APPROACH TO IMMUNOANALYSIS WITH FLUORESCENCE DETECTION [J].
POLLEMA, CH ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1825-1831
[32]   Integration of an immunosorbent assay system: Analysis of secretory human immunoglobulin A on polystyrene beads in a microchip [J].
Sato, K ;
Tokeshi, M ;
Odake, T ;
Kimura, H ;
Ooi, T ;
Nakao, M ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1144-1147
[33]  
SCHMALZING D, 1995, CLIN CHEM, V41, P1403
[34]  
SCHMIDTGAYK H, 2000, LECT MIPTEC LAB AUTO
[35]   RAPID IMMUNOASSAYS USING CAPILLARY ELECTROPHORESIS WITH FLUORESCENCE DETECTION [J].
SCHULTZ, NM ;
KENNEDY, RT .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3161-3165
[36]   CAPILLARY ELECTROPHORESIS BASED IMMUNOASSAY TO DETERMINE INSULIN CONTENT AND INSULIN-SECRETION FROM SINGLE ISLETS OF LANGERHANS [J].
SCHULTZ, NM ;
HUANG, L ;
KENNEDY, RT .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :924-929
[37]   CAVEATS FOR THE USE OF SURFACE-ADSORBED PROTEIN ANTIGEN TO TEST THE SPECIFICITY OF ANTIBODIES [J].
SCHWAB, C ;
BOSSHARD, HR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 147 (01) :125-134
[38]   Combining immunoassays with chromatographic and electrophoretic separation techniques - a review [J].
Shahdeo, K ;
Karnes, HT .
MIKROCHIMICA ACTA, 1998, 129 (1-2) :19-27
[39]  
Shultz-Lockyear LL, 1999, ELECTROPHORESIS, V20, P529, DOI 10.1002/(SICI)1522-2683(19990301)20:3<529::AID-ELPS529>3.0.CO
[40]  
2-7