Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues

被引:477
作者
Zhang, Edward [1 ]
Laufer, Jan [1 ]
Beard, Paul [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
关键词
D O I
10.1364/AO.47.000561
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A multiwavelength backward-mode planar photoacoustic scanner for 3D imaging of soft tissues to depths of several millimeters with a spatial resolution in the tens to hundreds of micrometers range is described. The system comprises a tunable optical parametric oscillator laser system that provides nanosecond laser pulses between 600 and 1200 nm for generating the photoacoustic signals and an optical ultrasound mapping system based upon a Fabry-Perot polymer film sensor for detecting them. The system enables photoacoustic signals to be mapped in 2D over a 50 mm diameter aperture in steps of 10 mu m with an optically defined element size of 64 mu m. Two sensors were used, one with a 22 mu m thick polymer film spacer and the other with a 38 mu m thick spacer providing -3 dB acoustic bandwidths of 39 and 22 MHz, respectively. The measured noise equivalent pressure of the 38 mu m sensor was 0.21 kPa over a 20 MHz measurement bandwidth. The instrument line-spread function (LSF) was measured as a function of position and the minimum lateral and vertical LSFs found to be 38 and 15 mu m, respectively. To demonstrate the ability of the system to provide high-resolution 3D images, a range of absorbing objects were imaged. Among these was a blood vessel phantom that comprised a network of blood filled tubes of diameters ranging from 62 to 300 mu m immersed in an optically scattering liquid. In addition, to demonstrate the applicability of the system to spectroscopic imaging, a phantom comprising tubes filled with dyes of different spectral characteristics was imaged at a range of wavelengths. It is considered that this type of instrument may provide a practicable alternative to piezoelectric-based photoacoustic systems for high-resolution structural and functional imaging of the skin microvasculature and other superficial structures. (C) 2008 Optical Society of America.
引用
收藏
页码:561 / 577
页数:17
相关论文
共 46 条
[1]   Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging [J].
Allen, Thomas J. ;
Beard, Paul C. .
OPTICS LETTERS, 2006, 31 (23) :3462-3464
[2]  
ASKENAZI S, 2005, P SOC PHOTO-OPT INS, V5697, P243
[3]   Two-dimensional ultrasound receive army using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging [J].
Beard, PC .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (06) :1002-1012
[4]   Transparent Fabry Perot polymer film ultrasound array for backward-mode photoacoustic imaging [J].
Beard, PC ;
Zhang, EZ ;
Cox, BT .
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING, 2004, 5320 :230-237
[5]   Photoacoustic imaging of blood vessel equivalent phantoms [J].
Beard, PC .
BIOMEDICAL OPTOACOUSTICS III, 2002, 4618 :54-62
[6]   Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones [J].
Beard, PC ;
Hurrell, AM ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :256-264
[7]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[8]  
BEARD PC, 1994, P SOC PHOTO-OPT INS, V2331, P112
[9]  
*BRIT STAND I, 1994, EN608251 BRIT STAND
[10]   Thermoacoustic tomography with integrating area and line detectors [J].
Burgholzer, P ;
Hofer, C ;
Paltauf, G ;
Haltmeier, M ;
Scherzer, O .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (09) :1577-1583