On line cation exchange for suppression of adduct formation in negative-ion electrospray mass spectrometry of nucleic acids

被引:88
作者
Huber, CG [1 ]
Buchmeiser, MR [1 ]
机构
[1] Univ Innsbruck, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
D O I
10.1021/ac980791b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One major difficulty in the analysis of nucleic acids by electrospray mass spectrometry is represented by the affinity of the polyanionic sugar-phosphate backbone for nonvolatile cations, especially ubiquitous sodium and potassium ions. A simple on-line sample preparation system comprising a microflow pumping system and 45-x 0.8-mm-i.d, microcolumns packed with weak or strong cation-exchange resins is described for the efficient removal of cations from nucleic acid samples. Samples were analyzed by flow injection analysis at a 3-5 mu L/min now of 10 mM triethylamine in 50% water-50% acetonitrile. After on-line desalting, mass spectra of oligonucleotides revealed no significant sodium adduct peaks. Moreover, signal-to-mise ratios were greatly enhanced compared to direct injection of the samples. Electrospray mass spectrometry with on-line sample preparation allowed accurate molecular mass determinations of picomole amounts of crude oligonucleotide preparations ranging in size from 8 to 80 nucleotides within a few minutes. The good linearity of the calibration plot (R(2) = 0.9988) over at least 2 orders of magnitude and a relative standard deviation in peak areas of less than 9% permitted the sensitive quantitative measurement of oligonucleotides in a concentration range of 0.2-20 mu M with selected-ion monitoring. Finally, the on-line sample preparation system was evaluated for the mass spectrometric analysis of complex oligonucleotide mixtures.
引用
收藏
页码:5288 / 5295
页数:8
相关论文
共 32 条
[1]   Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry [J].
Apffel, A ;
Chakel, JA ;
Fischer, S ;
Lichtenwalter, K ;
Hancock, WS .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1320-1325
[2]  
BAI J, 1995, RAPID COMMUN MASS SP, V8, P687
[3]   Infrared MALDI mass spectrometry of large nucleic acids [J].
Berkenkamp, S ;
Kirpekar, F ;
Hillenkamp, F .
SCIENCE, 1998, 281 (5374) :260-262
[4]   VARIOUS FACTORS INFLUENCING THE SIGNAL INTENSITY OF OLIGONUCLEOTIDES IN ELECTROSPRAY MASS-SPECTROMETRY [J].
BLEICHER, K ;
BAYER, E .
BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (06) :320-322
[5]   ANALYSIS OF OLIGONUCLEOTIDES USING COUPLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
BLEICHER, K ;
BAYER, E .
CHROMATOGRAPHIA, 1994, 39 (7-8) :405-408
[6]   Ring-opening-metathesis polymerization for the preparation of carboxylic-acid-functionalized, high-capacity polymers for use in separation techniques [J].
Buchmeiser, MR ;
Atzl, N ;
Bonn, GK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (39) :9166-9174
[7]   CHARGE-STATE REDUCTION OF OLIGONUCLEOTIDE NEGATIVE-IONS FROM ELECTROSPRAY-IONIZATION [J].
CHENG, XH ;
GALE, DC ;
UDSETH, HR ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :586-593
[8]   Molecular weight determination of plasmid DNA using electrospray ionization mass spectrometry [J].
Cheng, XH ;
Camp, DG ;
Wu, QY ;
Bakhtiar, R ;
Springer, DL ;
Morris, BJ ;
Bruce, JE ;
Anderson, GA ;
Edmonds, CG ;
Smith, RD .
NUCLEIC ACIDS RESEARCH, 1996, 24 (11) :2183-2189
[9]   INTERACTIONS OF POLYNUCLEOTIDES AND THEIR COMPONENTS .I. DISSOCIATION CONSTANTS OF BASES AND THEIR DERIVATIVES [J].
CLAUWAERT, J ;
STOCKX, J .
ZEITSCHRIFT FUR NATURFORSCHUNG PART B-CHEMIE BIOCHEMIE BIOPHYSIK BIOLOGIE UND VERWANDTEN GEBIETE, 1968, B 23 (01) :25-+
[10]   ELECTROSPRAY MASS-SPECTROMETRY FOR THE CHARACTERIZATION OF THE PURITY OF NATURAL AND MODIFIED OLIGODEOXYNUCLEOTIDES [J].
DEROUSSENT, A ;
LECAER, JP ;
ROSSIER, J ;
GOUYETTE, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (01) :1-4