Organotin speciation using fast flow glow discharge mass spectrometry

被引:7
作者
Newman, K [1 ]
Mason, RS [1 ]
机构
[1] Univ Wales Swansea, Dept Chem, Swansea SA2 8PP, W Glam, Wales
关键词
D O I
10.1039/b503002a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low power (<= 5 W) dc fast flow glow discharge (FFGD) ion source, coupled to gas chromatography, was evaluated for the speciation of tetramethyl-, tetraethyl-, triethyl- and tributyltin compounds. This source differs from other GC-GD techniques in that the sample is introduced into a. owing afterglow and not the active discharge region. The rapid flow of Ar gas carried the analyte towards the sampling cone, reducing diffusional losses and source fouling. The Ar discharge gas flow rate, source pressure, discharge voltage and ion extraction voltage (applied to the sampling cone) were optimised with respect to the Sn+ and SnH+ signals. Absolute detection limits of 0.2-0.4 pg were determined. The technique demonstrated excellent linearity (response indices 0.98-1.01) with a dynamic range of 3-4 orders of magnitude. The fundamental chemistry behind the trends observed is considered. The relative ion intensities were shown to vary with the source operating conditions. The ion extraction voltage, in particular, could be varied to obtain controllable fragmentation without affecting the primary discharge. From measurements of the relative ion kinetic energies, the observed fragmentation has been attributed to dissociation by electron bombardment in the ion extraction field. Structural information was discernible at the 0.03-10 ng level. The FFGD technique combines sensitive and selective detection with low cost and simplicity (relative to other MS methods). As such, FFGD-MS has potential applications in routine monitoring and identification of unknown organotin compounds in the environment.
引用
收藏
页码:830 / 838
页数:9
相关论文
共 48 条
[1]   Speciation of organotins in environmental samples by SPME-GC: comparison of four specific detectors: FPD, PFPD, MIP-AES and ICP-MS [J].
Aguerre, S ;
Lespes, G ;
Desauziers, V ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :263-269
[2]  
[Anonymous], 2003, Glow Discharge Plasmas in Analytical Spectroscopy
[3]   Application of experimental design in a method for screening sediments for global determination of organic tin by electrothermal atomic absorption spectrometry (ETAAS) [J].
Arambarri, I ;
Garcia, R ;
Millán, E .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (07) :955-960
[4]   Pulsed laser ablation and deposition of thin films [J].
Ashfold, MNR ;
Claeyssens, F ;
Fuge, GM ;
Henley, SJ .
CHEMICAL SOCIETY REVIEWS, 2004, 33 (01) :23-31
[5]   Headspace solid-phase micro-extraction gas chromatography-mass detection method for the determination of butyltin compounds in wines [J].
Azenha, M ;
Vasconcelos, MT .
ANALYTICA CHIMICA ACTA, 2002, 458 (01) :231-239
[6]   Improved routine speciation of organotin compounds in environmental samples by pulsed flame photometric detection [J].
Bancon-Montigny, C ;
Lespes, G ;
Potin-Gautier, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :149-158
[7]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261
[8]   Fundamental aspects and applications of glow discharge spectrometric techniques [J].
Bogaerts, A ;
Gijbels, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (01) :1-42
[9]  
Botana JC, 2002, J CHROMATOGR A, V963, P195
[10]  
CAI Y, 1992, ENVIRON SCI TECHNOL, V23, P615