摘要
Hemoglobin-based oxygen carriers (HBOC) may be ideal for monitoring circulating plasma volume (CV-P) and circulating blood volume (CV-B). We used an HBOC (Hemoglobin glutamer-200 [bovine], Oxyglobin(R); Biopure, Cambridge, MA) as an indicator for relative CV-B in the rabbit model. Accuracy of the technique was determined by comparison with the Evans blue dye (EBD) dilution technique in 19 anesthetized female New Zealand rabbits weighing 2.0 to 10.6 kg. The measurements were per formed at baseline, after hemorrhage (1/3 of CV-B), normovolemic hemodilution (replacement of 1/3 CV-B by Hextend(R); Abbot Laboratories, North Chicago, IL), and hypervolemic hemodilution (additional infusion of Hextend(R) in a volume equal to 1/3 of CV-B). Hemoglobin concentration was measured by using a HemoCue(R) photometer (HemoCue AB, Angelholm, Sweden). EBD concentration was analyzed by using linear regression to estimate Time 0 concentration; Time 0 was defined as EBD injection time. The difference between CV-P values determined by EBD and HBOC dilution was independent from the magnitude of the CV-P value. The relative bias was 1.29 mL and the precision (one SD) was 2.82 mL. The difference did not reach statistical significance.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 19 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Cardiovascular and hemorheological effects of three modified human hemoglobin solutions in hemodiluted rabbits [J].
Caron, A ;
Menu, P ;
Faivre-Fiorina, B ;
Labrude, P ;
Alayash, AI ;
Vigneron, C .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) :541-548
[3]   Blood substitutes: Fluids, drugs, or miracle solutions? [J].
Dietz, NM ;
Joyner, MJ ;
Warner, MA .
ANESTHESIA AND ANALGESIA, 1996, 82 (02) :390-405
[4]   Blood volume determination by the carbon monoxide method using a new delivery system:: Accuracy in critically ill humans and precision in an animal model [J].
Dingley, J ;
Foëx, BA ;
Swart, M ;
Findlay, G ;
DeSouza, PR ;
Wardrop, C ;
Willis, N ;
Smithies, M ;
Little, RA .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2435-2441
[5]  
FISHER SR, 1999, AM J PHYSIOL, V276, pH2194
[6]   REPEATED PLASMA-VOLUME DETERMINATION WITH THE EVANS BLUE-DYE DILUTION TECHNIQUE - THE METHOD AND A COMPUTER-PROGRAM [J].
FOLDAGER, N ;
BLOMQVIST, CG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1991, 21 (1-2) :35-41
[7]  
GULATI A, 1994, J LAB CLIN MED, V124, P125
[8]   MANIPULATING HEMODYNAMICS AND OXYGEN-TRANSPORT IN CRITICALLY ILL PATIENTS [J].
HINDS, C ;
WATSON, D .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (16) :1074-1075
[9]  
Intaglietta M, 1996, CARDIOVASC RES, V32, P632
[10]  
Jahr J S, 2000, Clin Lab Sci, V13, P173