Three-dimensional modeling for functional analysis of cardiac images: A review

被引:444
作者
Frangi, AF [1 ]
Niessen, WJ [1 ]
Viergever, MA [1 ]
机构
[1] Univ Utrecht, Med Ctr, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
关键词
cardiac imaging; functional analysis; model-based image analysis;
D O I
10.1109/42.906421
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Three-dimensional (3-D) imaging of the heart is a rapidly del eloping area of research in medical imaging, Advances in hardware and methods for fast spatio-temporal cardiac imaging are extending the frontiers of clinical diagnosis and research on cardiovascular diseases. In the last few Sears, many approaches hare been proposed to analyze images and extract parameters of cardiac shape and function from a variety of cardiac imaging modalities. In particular, techniques based on spatio-temporal geometric models have received considerable attention. This paper surveys the literature of tno decades of research on cardiac modeling. The contribution of the paper is three-fold: 1) to serve as a tutorial of the field for both clinicians and technologists, 2) to provide an extensive account of modeling techniques in a comprehensive and systematic manner, and 3) to critically review these approaches in terms of their performance and degree of clinical evaluation with respect to the final goal of cardiac functional analysis, From this review it is concluded that whereas 3-D model-based approaches have the capability. to improve the diagnostic value of cardiac images, issues as robustness, 3-D interaction, computational complexity and clinical validation still require significant attention.
引用
收藏
页码:2 / 25
页数:24
相关论文
共 229 条
  • [151] Left ventricular shape analysis from three-dimensional echocardiograms
    Munt, BI
    Leotta, DF
    Bolson, EL
    Coady, K
    Martin, RW
    Otto, CM
    Sheehan, FH
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (08) : 761 - 769
  • [152] Frequency-based nonrigid motion analysis: Application to four dimensional medical images
    Nastar, C
    Ayache, N
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1996, 18 (11) : 1067 - 1079
  • [153] NELSON TR, 1999, 3 DIMENSIONAL ULTRAS
  • [154] Geodesic deformable models for medical image analysis
    Niessen, WJ
    Romeny, BMT
    Viergever, MA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (04) : 634 - 641
  • [155] 3-DIMENSIONAL MYOCARDIAL DEFORMATIONS - CALCULATION WITH DISPLACEMENT FIELD FITTING TO TAGGED MR-IMAGES
    ODELL, WG
    MOORE, CC
    HUNTER, WC
    ZERHOUNI, EA
    MCVEIGH, ER
    [J]. RADIOLOGY, 1995, 195 (03) : 829 - 835
  • [156] ODonnell T, 1995, COMPUT CARDIOL, P5, DOI 10.1109/CIC.1995.482557
  • [157] ODONNELL T, 1996, COMPUT VIS PATTE JUN, P293
  • [158] Ohnesorge B, 2000, RADIOLOGE, V40, P111, DOI 10.1007/s001170050018
  • [159] FRONTS PROPAGATING WITH CURVATURE-DEPENDENT SPEED - ALGORITHMS BASED ON HAMILTON-JACOBI FORMULATIONS
    OSHER, S
    SETHIAN, JA
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 1988, 79 (01) : 12 - 49
  • [160] Osman NF, 1999, MAGN RESON MED, V42, P1048, DOI 10.1002/(SICI)1522-2594(199912)42:6<1048::AID-MRM9>3.0.CO