A search for optimal x-ray spectra in iodine contrast media mammography

被引:24
作者
Ullman, G [1 ]
Sandborg, M
Dance, DR
Yaffe, M
Carlsson, GA
机构
[1] Linkoping Univ, Dept Radiat Phys, IMV, SE-58185 Linkoping, Sweden
[2] Royal Marsden NHS Trust, Joint Dept Phys, London SW3 6JJ, England
[3] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
D O I
10.1088/0031-9155/50/13/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work was to search for the optimal x-ray tube voltage and anode-filter combination in digital iodine contrast media mammography. In the optimization, two entities were of interest: the average glandular dose, AGD, and the signal-to-noise ratio, SNR, for detection of diluted iodine contrast medium. The optimum is defined as the technique maximizing the figure of merit, SNR2/AGD. A Monte Carlo computer program was used which simulates the transport of photons from the x-ray tube through the compression plate, breast, breast support plate, anti-scatter grid and image detector. It computes the AGD and the SNR of an iodine detail inside the compressed breast. The breast thickness was varied between 2 and 8 cm with 10-90% glandularity. The tube voltage was varied between 20 and 55 kV for each anode material (Rh, Mo and W) in combination with either 25 mu m Rh or 0.05-0.5 mm Cu added filtration. The x-ray spectra were calculated with MCNP4C (Monte Carlo N-Particle Transport Code System, version 4C). A CsI scintillator was used as the image detector. The results for Rh/0.3mmCu, Mo/0.3mmCu and W/0.3mmCu were similar. For all breast thicknesses, a maximum in the figure of merit was found at approximately 45 kV for the Rh/Cu, Mo/Cu and W/Cu combinations. The corresponding results for the Rh/Rh combination gave a figure of merit that was typically lower and more slowly varying with tube voltage. For a 4 cm breast at 45 kV, the SNR2/AGD was 3.5 times higher for the Rh/0.3mmCu combination compared with the Rh/Rh combination. The difference is even larger for thicker breasts. The SNR2/AGD increases slowly with increasing Cu-filter thickness. We conclude that tube voltages between 41 and 55 kV and added Cu-filtration will result in significant dose advantage in digital iodine contrast media mammography compared to using the Rh/Rh anode/filter combination at 25-32 kV.
引用
收藏
页码:3143 / 3152
页数:10
相关论文
共 27 条
[1]  
Berger M. J., 1987, 873597 NBSIR
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]  
BRIESMEISTER JF, 2000, LA137037 LOS AL NAT
[4]   Human observer detection experiments with mammograms and power-law noise [J].
Burgess, AE ;
Jacobson, FL ;
Judy, PF .
MEDICAL PHYSICS, 2001, 28 (04) :419-437
[5]   Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study [J].
Dance, DR ;
Klang, AT ;
Sandborg, M ;
Skinner, CL ;
Smith, IAC ;
Carlsson, GA .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (874) :1056-1067
[6]   CALCULATION OF DOSE AND CONTRAST FOR 2 MAMMOGRAPHIC GRIDS [J].
DANCE, DR ;
PERSLIDEN, J ;
CARLSSON, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :235-248
[7]   THE COMPUTATION OF SCATTER IN MAMMOGRAPHY BY MONTE-CARLO METHODS [J].
DANCE, DR ;
DAY, GJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (03) :237-247
[8]   MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE [J].
DANCE, DR .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1211-1219
[10]  
DANCE DR, 1981, P PATIENT EXPOSURE R, P227