Optical coherence topography based on a two-dimensional smart detector array

被引:88
作者
Bourquin, S
Seitz, P
Salathé, RP
机构
[1] Ctr Suisse Elect & Microtech, Image Sensing Grp, CH-8048 Zurich, Switzerland
[2] Ecole Polytech Fed Lausanne, Inst Opt Appl, CH-1015 Lausanne, Switzerland
关键词
D O I
10.1364/OL.26.000512
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A lo rv-coherence reflectometer based on a conventional Michelson interferometer and a novel silicon detector chip with a two-dimensional array of pixels that allows parallel heterodyne detection is presented. We demonstrate acquisition of three-dimensional images with more than 100,000 voxels per scan at a sensitivity of -58 dB and a rate of 6 Hz. (C) 2001 Optical Society of America.
引用
收藏
页码:512 / 514
页数:3
相关论文
共 11 条
[1]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[2]   Video-rate optical low-coherence reflectometry based on a linear smart detector array [J].
Bourquin, S ;
Monterosso, V ;
Seitz, P ;
Salathé, RP .
OPTICS LETTERS, 2000, 25 (02) :102-104
[3]   HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES [J].
CLIVAZ, X ;
MARQUISWEIBLE, F ;
SALATHE, RP ;
NOVAK, RP ;
GILGEN, HH .
OPTICS LETTERS, 1992, 17 (01) :4-6
[4]   GUIDED-WAVE REFLECTOMETRY WITH MICROMETER RESOLUTION [J].
DANIELSON, BL ;
WHITTENBERG, CD .
APPLIED OPTICS, 1987, 26 (14) :2836-2842
[5]   3-DIMENSIONAL SENSING OF ROUGH SURFACES BY COHERENCE RADAR [J].
DRESEL, T ;
HAUSLER, G ;
VENZKE, H .
APPLIED OPTICS, 1992, 31 (07) :919-925
[6]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design [J].
Rollins, AM ;
Ung-arunyawee, R ;
Chak, A ;
Wong, RCK ;
Kobayashi, K ;
Sivak, MV ;
Izatt, JA .
OPTICS LETTERS, 1999, 24 (19) :1358-1360
[9]   NEW MEASUREMENT SYSTEM FOR FAULT LOCATION IN OPTICAL WAVE-GUIDE DEVICES BASED ON AN INTERFEROMETRIC-TECHNIQUE [J].
TAKADA, K ;
YOKOHAMA, I ;
CHIDA, K ;
NODA, J .
APPLIED OPTICS, 1987, 26 (09) :1603-1606
[10]   Rapid acquisition of in vivo biological images by use of optical coherence tomography [J].
Tearney, GJ ;
Bouma, BE ;
Boppart, SA ;
Golubovic, B ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1996, 21 (17) :1408-1410