Effect of chemical composition on hydrophobicity and zeta potential of plasma sprayed HA/CaO-P2O5 glass coatings

被引:34
作者
Ferraz, MP
Monteiro, FJ
Serro, AP
Saramago, B
Gibson, IR
Santos, JD
机构
[1] INEB, Lab Biomat, P-4150 Oporto, Portugal
[2] Univ Porto, Fac Engn, Dept Met & Mat Engn, P-4099 Oporto, Portugal
[3] Inst Super Tecn, Ctr Quim Estrutural, P-1096 Lisbon, Portugal
[4] Univ London Queen Mary & Westfield Coll, IRC Biomed Mat, London E1 4NS, England
关键词
hydroxyapatite glass composites; coatings; hydrophobicity; surface tension zeta potential;
D O I
10.1016/S0142-9612(01)00059-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multilayered plasma sprayed coatings on the surface of Ti-6Al-4V alloys have been prepared, which were composed of an underlayer of HA and a surface layer of a CaO-P2O5 glass-HA composite, with 2 or 4 wt% of glass. Contact angle and surface tension variation with time, for both water and a protein solution, were determined by the sessile and pendent drop methods respectively using the ADSA-P software. Wettability studies showed that hydrophobicity of the coatings increase with the glass addition. The work of adhesion of albumin was also altered in a controlled manner by the addition of the CaO-P2O5 glass, being lower on the composite coatings than on HA. Zeta potential (ZP) results showed that composite coatings presented a higher net negative charge than HA coatings and that ZP values were also influenced by the content of the glass. This study demonstrated that the surface properties of those coatings may be modified by the addition of CaO-P2O5 glass. (C) 2001 Published by Elsevier Science Ltd.
引用
收藏
页码:3105 / 3112
页数:8
相关论文
共 30 条
[1]  
ADAMSON W, 1990, PHYSICAL CHEM SURFAC
[2]   COMPUTATIONAL EVALUATION OF AXISYMMETRICAL DROP SHAPE ANALYSIS-PROFILE (ADSA-P) [J].
CHENG, P ;
NEUMANN, AW .
COLLOIDS AND SURFACES, 1992, 62 (04) :297-305
[3]   AUTOMATION OF AXISYMMETRIC DROP SHAPE-ANALYSIS FOR MEASUREMENT OF INTERFACIAL-TENSIONS AND CONTACT ANGLES [J].
CHENG, P ;
LI, D ;
BORUVKA, L ;
ROTENBERG, Y ;
NEUMANN, AW .
COLLOIDS AND SURFACES, 1990, 43 (2-4) :151-167
[4]   COMPARISON OF THE EARLY PRODUCTION OF EXTRACELLULAR-MATRIX ON DENSE HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IN CELL AND ORGAN-CULTURE [J].
COURTENEYHARRIS, RG ;
KAYSER, MV ;
DOWNES, S .
BIOMATERIALS, 1995, 16 (06) :489-495
[5]   Adult human bone cells from jaw bones cultured on plasma-sprayed or polished surfaces of titanium or hydroxylapatite discs [J].
DeSantis, D ;
Guerriero, C ;
Nocini, PF ;
Ungersbock, A ;
Richards, G ;
Gotte, P ;
Armato, U .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (01) :21-28
[6]   In vitro growth and differentiation of osteoblast-like human bone marrow cells on glass reinforced hydroxyapatite plasma-sprayed coatings [J].
Ferraz, MP ;
Fernandes, MH ;
Cabral, AT ;
Santos, JD ;
Monteiro, FJ .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (09) :567-576
[7]  
Ferraz MP, 1999, J BIOMED MATER RES, V45, P376, DOI 10.1002/(SICI)1097-4636(19990615)45:4<376::AID-JBM13>3.0.CO
[8]  
2-S
[9]   COMPARATIVE BIOLOGICAL PROPERTIES OF HA PLASMA-SPRAYED COATINGS HAVING DIFFERENT CRYSTALLINITIES [J].
FRAYSSINET, P ;
TOURENNE, F ;
ROUQUET, N ;
CONTE, P ;
DELGA, C ;
BONEL, G .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (01) :11-17
[10]   GLOBULAR-PROTEINS AT SOLID-LIQUID INTERFACES [J].
HAYNES, CA ;
NORDE, W .
COLLOIDS AND SURFACES B-BIOINTERFACES, 1994, 2 (06) :517-566