摘要
Although polyethylene components have been used in the human joint for over 30 years, wear simulation studies are fundamental to assess wear resistance of total joint replacements. This assessment will help to obtain quality control and acquire further knowledge of the tribological processes that involve joint prostheses. As a result, the risk of implant failure of innovative prostheses will be reduced. The aim of the present study was to investigate the influence on wear of the polyethylene tibial inserts against metallic femoral components using a knee simulator following a standardized kinematics protocol (ISO/CD 14243-3.2). Four intact "small" size specimens of the tibial MP 913 were tested in a four-station knee wear simulator for two million cycles. The volumetric weight loss for the ultra-high-molecular-weight-polyethylene (UHMWPE) tibial inserts was 44 +/- 2, 45 +/- 3, and 47 +/- 3 mg for the specimens #1-3, respectively. This study demonstrated a good repeatability among the stations of the knee simulator obtaining weight loss values congruent with those found by other authors using similar test conditions.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 21 条
[1]
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[2]
Investigation of wear of knee prostheses in a new displacement/force-controlled simulator [J].
Barnett, PI ;
McEwen, HMJ ;
Auger, DD ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :51-61
[3]
Comparison of wear in a total knee replacement under different kinematic conditions [J].
Barnett, PI ;
Fisher, J ;
Auger, DD ;
Stone, MH ;
Ingham, E .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) :1039-1042
[4]
Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics [J].
Benson, LC ;
DesJardins, JD ;
LaBerge, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :496-504
[5]
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[6]
The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity [J].
DesJardins, JD ;
Walker, PS ;
Haider, H ;
Perry, J .
JOURNAL OF BIOMECHANICS, 2000, 33 (10) :1231-1242
[7]
*ISO, 2002, IMPL SURG TOT KNEE 1
[8]
*ISO, 1998, IMPL SURG ULTR HI 2
[9]
ISO, 2004, IMPL SURG WEAR TOT 3
[10]
JOHNSON T, 2000, DEV KNEE WEAR TEST M