Development of an optical RNA-based aptasensor for C-reactive protein

被引:79
作者
Bini, A. [1 ]
Centi, S. [1 ]
Tombelli, S. [1 ]
Minunni, M. [1 ]
Mascini, M. [1 ]
机构
[1] Univ Florence, Dipartimento Chim, I-50019 Florence, Italy
关键词
aptamer; C-reactive protein; surface plasmon resonance;
D O I
10.1007/s00216-007-1736-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of a RNA-aptamer-based optical biosensor (aptasensor) for C-reactive protein (CRP) is reported. CRP is an important clinical biomarker; it was the first acute-phase protein to be discovered (1930) and is a sensitive systemic marker of inflammation and tissue damage. It has also a prognostic value for patients with acute coronary syndrome. The average concentration of CRP in serum is 0.8 ppm and it increases in response to a variety of inflammatory stimuli, such as trauma, tissue necrosis, infection and myocardial infarction. The interaction between the 44-base RNA aptamer and the target analyte CRP is studied. In particular, the influence of the aptamer immobilization procedure (chemistry, length, concentration), as well as the binding conditions, i.e., the influence on the binding of different buffers, the presence of Ca2+ ion and the specificity (against human serum albumin) have been evaluated. Using the best working conditions, we achieved a detection limit of 0.005 ppm, with good selectivity towards human serum albumin. Some preliminary experiments in serum are reported.
引用
收藏
页码:1077 / 1086
页数:10
相关论文
共 40 条
[1]   Analytical performances of aptamer-based sensing for thrombin detection [J].
Bini, Alessandra ;
Minunni, Maria ;
Tombelli, Sara ;
Centi, Sonia ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :3016-3019
[2]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[3]  
Clearfield Michael B, 2005, J Am Osteopath Assoc, V105, P409
[4]  
Davis TM, 2001, METHOD ENZYMOL, V340, P22
[5]   Is a closing "GA pair" a rule for stable loop-loop RNA complexes? [J].
Ducongé, F ;
Di Primo, C ;
Toulmé, JJ .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2000, 275 (28) :21287-21294
[6]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[7]   Selection and analytical applications of aptamers [J].
Hamula, Camille L. A. ;
Guthrie, Jeffrey W. ;
Zhang, Hongquan ;
Li, Xing-Fang ;
Le, X. Chris .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :681-691
[8]   Nucleic acid-based fluorescence sensors for detecting proteins [J].
Heyduk, E ;
Heyduk, T .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :1147-1156
[9]   Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing [J].
Hu, WP ;
Hsu, HY ;
Chiou, A ;
Tseng, KY ;
Lin, HY ;
Chang, GL ;
Chen, SJ .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1631-1637
[10]  
Jayasena SD, 1999, CLIN CHEM, V45, P1628