Intramedullary nails: some design features of the distal end

被引:27
作者
Wang, CJ
Brown, CJ [1 ]
Yettram, AL
Procter, P
机构
[1] Brunel Univ, Dept Mech Engn, Uxbridge UB8 3PH, Middx, England
[2] Stryker Trauma SA, Chem Pont Centenaire 110, CH-1228 Geneva, Switzerland
关键词
fractured femur; proximal femoral nails; intramedullary nails; finite element method;
D O I
10.1016/S1350-4533(03)00098-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Intramedullary nails are used to stabilise fractures of the proximal femur. The nail acts by transferring loads from the proximal fraction to the rest of the femoral shaft. The way in which this occurs depends to a large extent on the design of the distal end of the nail. This is not dissimilar to the situation with regard to load shedding (or load transfer) from the femoral component of a total hip replacement. A finite element model of a fractured femur with either a neck or a subtrochanteric fracture is set up to investigate the effects of nail length. nail distal stiffness and material stiffness on the structural behaviour of the system. Specifically what is considered is the influence of these parameters on the stress across the fracture and the normal pressure that the nail exerts on the endosteum of the femoral diaphysis. It is found that a longer nail could produce higher contact stress between the tip of the nail and the endosteum. Also, this contact stress is reduced when the distal region of the nail is made more flexible either by incorporating longitudinal slots or by using a material with a lower modulus of elasticity. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:789 / 794
页数:6
相关论文
共 12 条
[1]
FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[2]
Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures - A prospective, randomized study of one hundred patients [J].
Hardy, DCR ;
Descamps, PY ;
Krallis, P ;
Fabeck, L ;
Smets, P ;
Bertens, CL ;
Delince, PE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :618-630
[3]
Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail [J].
Kawaguchi, S ;
Sawada, K ;
Nabeta, Y .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (01) :47-53
[4]
PREVENTION OF FRACTURE AT THE DISTAL LOCKING SITE OF THE GAMMA-NAIL [J].
LACROIX, H ;
ARWERT, H ;
SNIJDERS, CJ ;
FONTIJNE, WPJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (02) :274-276
[5]
Miles A. W., 1992, STRAIN MEASUREMENT B
[6]
SCHIPPER IB, 2002, CLIN ORTH RELATED RE, V405, P277
[7]
NEW DESIGN OF HIP-PROSTHESIS USING CARBON-FIBER REINFORCED COMPOSITE [J].
SHIRANDAMI, R ;
ESAT, II .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (01) :19-22
[8]
IS STEM LENGTH IMPORTANT IN UNCEMENTED ENDOPROSTHESES [J].
TANNER, KE ;
YETTRAM, AL ;
LOEFFLER, M ;
GOODIER, WD ;
FREEMAN, MAR ;
BONFIELD, W .
MEDICAL ENGINEERING & PHYSICS, 1995, 17 (04) :291-296
[9]
FAILURE OF THE GAMMA-NAIL IN A HIGHLY UNSTABLE PROXIMAL FEMUR FRACTURE - REPORT OF 4 CASES ENCOUNTERED IN THE NETHERLANDS [J].
VANDENBRINK, WA ;
JANSSEN, IMC .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) :53-56
[10]
Intramedullary femoral nails: one or two lag screws? A preliminary study [J].
Wang, CJ ;
Brown, CJ ;
Yettram, AL ;
Procter, P .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (09) :613-624