Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer

被引:37
作者
Detry-Morel, Michele [1 ]
Jamart, Jacques [2 ]
Pourjavan, Saveh
机构
[1] Catholic Univ Louvain, Dept Ophthalmol, St Luc Univ Hosp, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, Mt Godinne Univ Hosp, Yvoir, Belgium
关键词
Central corneal thickness; Corneal hysteresis; Goldmann applanation tonometry; Ocular hypertension; Ocular Response Analyzer; Open-angle glaucoma; INTRAOCULAR-PRESSURE; THICKNESS; HYSTERESIS; HYPERTENSION; GLAUCOMA; PARAMETERS; IMPACT;
D O I
10.5301/EJO.2010.2150
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE. To compare corneal hysteresis (CH) and corneal resistance factor (CRF) measured with the Ocular Response Analyzer (ORA) in patients with primary open-angle glaucoma (POAG), patients with ocular hypertension (OHT), and normal subjects (NL); and to assess correlations of CH and CRF with corneal-compensated intraocular pressure (IOPcc), Goldmann applanation tonometry (GAT), glaucoma type, central corneal thickness (CCT), previous filtering procedure, and antiglaucoma medications. METHODS. A total of 108 POAG, 22 OHT, and 24 NL were enrolled in this observational study. Goldmann applanation tonometry and ORA were performed in a randomized sequence followed by pachymetry. One eye per subject was selected at random for analysis. Chi-square, Wilcoxon, and Kruskal-Wallis tests were used for comparison and Spearman coefficient for assessing correlations. RESULTS. Mean CH and CRF were significantly lower in POAG than in OHT and NL. Ocular Response Analyzer IOPcc overestimated IOP compared to GAT only in POAG. This difference increased with higher GAT. Goldmann applanation tonometry and IOPcc were correlated. Corneal hysteresis was negatively correlated with age in POAG. Corneal resistance factor and CH were positively correlated with CCT in POAG and OHT. Unlike CRF, CH was not correlated with GAT in POAG and OHT. Corneal-compensated intraocular pressure was not correlated with CCT. Difference between GAT and IOPcc was not CCT dependent. Corneal hysteresis and CRF were comparable in POAG and NTG, unchanged after filtering procedure. Corneal hysteresis was not altered by topical medications. Corneal resistance factor was significantly lower in treated eyes and those receiving prostaglandin analogues with no correlation with the treatment duration. CONCLUSIONS. Patients with glaucoma seem to have distinctive corneal biomechanical properties compared to OHT and NL. They may be influenced by many other unknown subparameters.
引用
收藏
页码:138 / 148
页数:11
相关论文
共 28 条
[1]
Age related compliance of the lamina cribrosa in human eyes [J].
Albon, J ;
Purslow, PP ;
Karwatowski, WSS ;
Easty, DL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (03) :318-323
[2]
Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma [J].
Ang, Ghee Soon ;
Bochmann, Frank ;
Townend, John ;
Azuara-Blanco, Augusto .
JOURNAL OF GLAUCOMA, 2008, 17 (04) :259-262
[3]
Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, Ocular Response Analyzer, and Goldmann tonometry in glaucomatous eyes [J].
Annette, Hager ;
Kristina, Loge ;
Bernd, Schroeder ;
Mark-Oliver, Fuellhas ;
Wolfgang, Wiegand .
JOURNAL OF GLAUCOMA, 2008, 17 (05) :361-365
[4]
Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON) [J].
Bochmann, Frank ;
Ang, Ghee S. ;
Azuara-Blanco, Augusto .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (05) :735-738
[5]
Changes in central corneal thickness over time - The Ocular Hypertension Treatment Study [J].
Brandt, James D. ;
Gordon, Mae O. ;
Beiser, Julia A. ;
Lin, Shan C. ;
Alexander, Monica Y. ;
Kass, Michael A. .
OPHTHALMOLOGY, 2008, 115 (09) :1550-1556
[6]
Central corneal thickness and measured IOP response to topical ocular hypotensive medication in the ocular hypertension treatment study [J].
Brandt, JD ;
Beiser, JA ;
Gordon, MO ;
Kass, MA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (05) :717-722
[7]
Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of Intraocular pressure [J].
Broman, Aimee Teo ;
Congdon, Nathan G. ;
Bandeen-Roche, Karen ;
Quigley, Harry A. .
JOURNAL OF GLAUCOMA, 2007, 16 (07) :581-588
[8]
Corneal structure and biomechanics: impact on the diagnosis and management of glaucoma [J].
Brown, Kimberly E. ;
Congdon, Nathan G. .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (04) :338-343
[9]
The heritability of corneal hysteresis and ocular pulse amplitude - A twin study [J].
Carbonaro, Francis ;
Andrew, Toby ;
Mackey, David A. ;
Spector, Tim D. ;
Hammond, Chris J. .
OPHTHALMOLOGY, 2008, 115 (09) :1545-1549
[10]
Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875