Assessment of nanocomposite alumina supported on multi-wall carbon nanotubes as sorbent for on-line nickel preconcentration in water samples

被引:64
作者
Amais, Renata S.
Ribeiro, Juliana S.
Segatelli, Mariana G.
Yoshida, Inez V. P.
Luccas, Pedro O.
Tarley, Cesar R. T. [1 ]
机构
[1] Univ Fed Alfenas, Dept Ciencias Exatas, BR-37130000 Alfenas, Brazil
[2] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Al(2)O(3)/MWCNT nanocomposite; sorbent flow preconcentration; nickel; FAAS;
D O I
10.1016/j.seppur.2007.07.024
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The performance of Al(2)O(3)/MWCNT nanocomposite as a new sorbent for Ni(II) preconcentration from water samples, using a flow injection system coupled to flame atomic absorption spectrometry, is described in this study. The characterization of the nanocomposite was carried out by using thermogravimetric analysis (TG), BET surface area, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The analytical procedure involved the preconcentration of 20 mL Ni(II) Solution buffered with 0.24 mol L(-1) amoniacal buffer at pH 9.0 through 50 mg of the nanocomposite packed into a minicolumn, followed by the elution in countercurrent using 1.0 mol L(-1) HNO(3) solution at flow rate of 5.0 mL min(-1). Factors involved in the flow and chemical performance of the system were optimized by means of factorial design. The method provided a preconcentration factor of 20.9, linear range varying from 13.6 up to 230.0 mu g L(-1) and detection limit of 4.1 mu g L(-1) under optimized conditions. The proposed method was validated from recovery tests for Ni(R) determination in water samples, whose values ranged from 95.7 up to 99. 1 %, thus confirming the accuracy of the proposed method and the feasibility of Al(2)O(3)/MWCNT nanocomposite in the field of solid-phase preconcentration procedures. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 128
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 2004, ELEMENTS THEIR COMPO, DOI DOI 10.1002/9783527619634
[2]   On-line liquid-liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters [J].
Anthemidis, AN ;
Zachariadis, GA ;
Farastelis, CG ;
Stratis, JA .
TALANTA, 2004, 62 (03) :437-443
[3]  
Belitz H.D., 1999, FOOD CHEM, V2nd
[4]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[5]   Chromium adsorption by aligned carbon nanotubes supported ceria nanoparticles [J].
Di, ZC ;
Ding, J ;
Peng, XJ ;
Li, YH ;
Luan, ZK ;
Liang, J .
CHEMOSPHERE, 2006, 62 (05) :861-865
[6]  
EPA, 2002, NAT PRIM DRINK WAT S
[7]  
Fang Z., 1993, FLOW INJECTION SEPAR
[8]   Solid-phase extraction system for Pb (II) ions enrichment based on multiwall carbon nanotubes coupled on-line to flame atomic absorption spectrometry [J].
Francisco Barbosa, Adriano ;
Gava Segatelli, Mariana ;
Cesar Pereira, Arnaldo ;
de Santana Santos, Antonio ;
Tatsuo Kubota, Lauro ;
Orival Luccas, Pedro ;
Ricardo Teixeira Tarley, Cesar .
TALANTA, 2007, 71 (04) :1512-1519
[9]   Chemistry of alumina, reactions in aqueous solution and its application in water treatment [J].
Kasprzyk-Hordern, B .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2004, 110 (1-2) :19-48
[10]   Determination of nickel in fingernails and forearm skin (stratum corneum) [J].
Kristiansen, J ;
Christensen, JM ;
Henriksen, T ;
Nielsen, NH ;
Menné, T .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :265-272