3-D sonographic volume measurement of the cerebral ventricular system: In vitro validation

被引:22
作者
Kampmann, W
Walka, MM
Vogel, M
Obladen, M
机构
[1] Humboldt Univ, Virchow Hosp, Charite, Dept Neonatol, D-13353 Berlin, Germany
[2] German Heart Ctr, Berlin, Germany
关键词
computer-assisted image-processing; infant; newborn; ultrasound (US) in infants and children; brain ventricles; phantoms;
D O I
10.1016/S0301-5629(98)00058-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This in vitro study evaluates the accuracy and observer dependency of a freehand three-dimensional (3-D) ultrasound system for measuring cerebral ventricular volume in infants. A sphere, a cylinder, and three cerebral ventricle phantoms were made of agarose and embedded in an echogenic matrix after measuring true volumes by water displacement. Volumes of the models were calculated by 3-D software after manual contour marking on ultrasound cross-sections. Mean +/- SD sonographic volume was 94.6% +/- 7.3% (n = 130) of true volumes. Intraobserver variation (n = 10) was 2.3%-53% for complete investigation (scanning and marking), and 1.8%-4.1% for marking alone. Difference of means (n = 10) between two observers was 7.6% to 10.8% for complete investigation, and 0.6% to 1.6% for the marking process. We conclude that 3-D freehand ultrasonography may be useful for examining ventricle dilatation in infancy. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1169 / 1174
页数:6
相关论文
共 18 条
[1]   EFFECT OF AIR-DRYING ON DEMINERALIZED AND ON SOUND CORONAL HUMAN DENTIN - A STUDY ON DENSITY AND ON LESION SHRINKAGE [J].
ARENDS, J ;
RUBEN, J .
CARIES RESEARCH, 1995, 29 (01) :14-19
[2]  
BRANN BS, 1990, J ULTRAS MED, V9, P1
[3]  
BRANN BS, 1990, J ULTRAS MED, V9, P9
[4]   AN EASILY MADE, LOW-COST, TISSUE-LIKE ULTRASOUND PHANTOM MATERIAL [J].
BUDE, RO ;
ADLER, RS .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (04) :271-273
[5]   NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL [J].
BURLEW, MM ;
MADSEN, EL ;
ZAGZEBSKI, JA ;
BANJAVIC, RA ;
SUM, SW .
RADIOLOGY, 1980, 134 (02) :517-520
[6]   INTRAOBSERVER AND INTEROBSERVER RELIABILITY IN ASSESSMENT OF NEONATAL CRANIAL ULTRASOUNDS [J].
CORBETT, SS ;
ROSENFELD, CR ;
LAPTOOK, AR ;
RISSER, R ;
MARAVILLA, AM ;
DOWLING, S ;
LASKY, R .
EARLY HUMAN DEVELOPMENT, 1991, 27 (1-2) :9-17
[7]   3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION [J].
DETMER, PR ;
BASHEIN, G ;
HODGES, T ;
BEACH, KW ;
FILER, EP ;
BURNS, DH ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :923-936
[8]   IN-VITRO EVALUATION OF 3-DIMENSIONAL ULTRASONOGRAPHY IN VOLUME ESTIMATION OF ABDOMINAL ORGANS [J].
GILJA, OH ;
THUNE, N ;
MATRE, K ;
HAUSKEN, T ;
ODEGAARD, S ;
BERSTAD, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02) :157-165
[9]   Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor [J].
Hughes, SW ;
DArcy, TJ ;
Maxwell, DJ ;
Chiu, W ;
Milner, A ;
Saunders, JE ;
Sheppard, RJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (05) :561-572
[10]  
KING DL, 1991, J ULTRAS MED, V10, P77