Strategies for the liquid chromatographic-mass spectrometric analysis of non-polar compounds

被引:87
作者
Hayen, H
Karst, U
机构
[1] Univ Twente, Dept Chem Anal, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
关键词
liquid chromatography-mass spectrometry; mass spectrometry; reviews; electrochemical conversion; atmospheric pressure photoionization; atmospheric pressure electron capture negative ion-MS; coordination ionspray; non-polar compounds;
D O I
10.1016/S0021-9673(03)00505-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization and atmospheric pressure chemical ionization (APCI) have evolved recently as very useful tools for the liquid chromatographic-mass spectrometric (LC-MS) analysis of polar substances. Non-polar compounds, however, are difficult to analyze with these atmospheric pressure ionization techniques due to their soft ionization mechanism. Recently, new approaches have been introduced which are likely to overcome this obstacle, at least partly. On-line electrochemical conversion of the analytes to more polar reaction products, atmospheric pressure photoionization, atmospheric pressure electron capture negative ion-MS and coordination ionspray-MS are four techniques which are presented in detail, compared and discussed critically with respect to their current status and future perspectives. Particular focus is directed from a chemical viewpoint on the substance groups which are accessible by each of the new approaches. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:549 / 565
页数:17
相关论文
共 115 条
[1]   LC/ESI-MS DETERMINATION OF PROTEINS USING CONVENTIONAL LIQUID-CHROMATOGRAPHY AND ULTRASONICALLY ASSISTED ELECTROSPRAY [J].
BANKS, JF ;
QUINN, JP ;
WHITEHOUSE, CM .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3688-3695
[2]   Characterization of fullerenes and fullerene derivatives by nanospray [J].
Barrow, MP ;
Feng, XD ;
Wallace, JI ;
Boltalina, OV ;
Taylor, R ;
Derrick, PJ ;
Drewello, T .
CHEMICAL PHYSICS LETTERS, 2000, 330 (3-4) :267-274
[3]  
Bayer E, 1999, ANGEW CHEM INT EDIT, V38, P992, DOI 10.1002/(SICI)1521-3773(19990401)38:7<992::AID-ANIE992>3.0.CO
[4]  
2-K
[5]  
BITTENSCATTANEO B, 1991, ELECTROANALYTICAL CH, V17
[6]   MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[7]   QUANTIFICATION OF L-TRYPTOPHAN AND L-KYNURENINE BY LIQUID-CHROMATOGRAPHY ELECTRON-CAPTURE NEGATIVE-ION CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
BONI, RL ;
SIMPSON, JT ;
NARITSIN, DB ;
SAITO, K ;
MARKEY, SP .
BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (01) :27-32
[8]   USE OF A POROUS ELECTRODE FOR IN-SITU MASS SPECTROMETRIC DETERMINATION OF VOLATILE ELECTRODE REACTION PRODUCTS [J].
BRUCKENSTEIN, S ;
RAOGADDE, R .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1971, 93 (03) :793-+
[9]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[10]   Electron capture ionization of explosives with a microflow rate particle beam interface [J].
Cappiello, A ;
Famiglini, G ;
Lombardozzi, A ;
Massari, A ;
Vadala, GG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (08) :753-758