Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings

被引:78
作者
Busch, S. [1 ]
Johnson, T. R. C. [1 ]
Wintersperger, B. J. [1 ]
Minaifar, N. [1 ]
Bhargava, A. [1 ]
Rist, C. [1 ]
Reiser, M. F. [1 ]
Becker, C. [1 ]
Nikolaou, K. [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
关键词
cardiac function; coronary angiography; computed tomography;
D O I
10.1007/s00330-007-0767-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 +/- 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 +/- 41.9 ml and 54.9 +/- 29.6 ml, respectively, compared with 132.1 +/- 40.8 ml EDV and 57.6 +/- 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 +/- 12.4% in DSCT and 57.9 +/- 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P=0.0024), 0.79 for ESV (P=0.0031) and 0.64 for EF (P=0.0168). The kappa value of inter-observer variability were amounted to 0.85 for EDV, ESV and EF. DSCT offers the possibility to quantify left ventricular function from coronary CT angiography datasets with sufficient diagnostic accuracy, adding to the value of the modality in a comprehensive cardiac assessment. The observed differences in the measured values may be due to different post-processing methods and physiological reactions to contrast material injection without beta-blocker medication.
引用
收藏
页码:570 / 575
页数:6
相关论文
共 18 条
[1]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[2]   Utility of fast cine magnetic resonance imaging and display for the detection of myocardial ischemia in patients not well suited for second harmonic stress echocardiography [J].
Hundley, WG ;
Hamilton, CA ;
Thomas, MS ;
Herrington, DM ;
Salido, TB ;
Kitzman, DW ;
Little, WC ;
Link, KM .
CIRCULATION, 1999, 100 (16) :1697-1702
[3]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415
[4]   Left ventricular function studied with MDCT [J].
Juergens, KU ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2006, 16 (02) :342-357
[5]   Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: Initial experience [J].
Juergens, KU ;
Grude, M ;
Maintz, D ;
Fallenberg, EM ;
Wichter, T ;
Heindel, W ;
Fischbach, R .
RADIOLOGY, 2004, 230 (02) :403-410
[6]  
LASALARIE JC, 2007, EUR RADIOL
[7]   Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography:: comparison with magnetic resonance imaging [J].
Mahnken, AH ;
Mühlenbruch, G ;
Koos, R ;
Stanzel, S ;
Busch, PS ;
Niethammer, M ;
Günther, RW ;
Wildberger, JE .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1416-1423
[8]   Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction [J].
Mahnken, AH ;
Koos, R ;
Katoh, M ;
Spuentrup, E ;
Busch, P ;
Wildberger, JE ;
Kühl, HP ;
Günther, RW .
EUROPEAN RADIOLOGY, 2005, 15 (04) :714-720
[9]   Global left ventricular function in cardiac CT.: Evaluation of an automated 3D region-growing segmentation algorithm [J].
Mühlenbruch, G ;
Das, M ;
Hohl, C ;
Wildberger, JE ;
Rinck, D ;
Flohr, TG ;
Koos, R ;
Knackstedt, C ;
Günther, RW ;
Mahnken, AH .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1117-1123
[10]   Assessment of cardiac function using multidetector row computed tomography [J].
Orakzai, Sarwar H. ;
Orakzai, Raza H. ;
Nasir, Khurram ;
Budoff, Matthew J. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (04) :555-563