Stability of transforaminal lumbar interbody fusion in the setting of retained facets and posterior fixation using transfacet or standard pedicle screws

被引:25
作者
Chin, Kingsley R. [1 ,2 ]
Reis, Marco T. [3 ]
Reyes, Phillip M. [3 ]
Newcomb, Anna G. U. [3 ]
Neagoe, Anda [3 ]
Gabriel, Josue P. [4 ]
Sung, Roger D. [5 ]
Crawford, Neil R. [3 ]
机构
[1] Florida Atlantic Univ, Charles E Schmidt Coll Med, Boca Raton, FL 33431 USA
[2] LES Spine Inst, Dept Orthopaed Surg, Ft Lauderdale, FL 33311 USA
[3] Barrow Neurol Inst, St Josephs Hosp & Med Ctr, Dept Neurosurg, Phoenix, AZ 85013 USA
[4] Grant Med Ctr, Dept Orthoped, Columbus, OH 43215 USA
[5] Colorado Springs Orthopaed Grp, Spine Ctr, Colorado Springs, CO 80909 USA
关键词
Transforaminal lumbar interbody fusion; Transfacet pedicle screws; LES; Less Exposure Surgery; Facet; BIOMECHANICAL EVALUATION; LEVEL POSTERIOR; SPINE; TERM;
D O I
10.1016/j.spinee.2013.06.103
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND CONTEXT: The transforaminal lumbar interbody fusion (TLIF) technique supplements posterior instrumented lumbar spine fusion and has been tested with different types of screw fixation for stabilization. Transforaminal lumbar interbody fusion is usually placed through a unilateral foraminal approach after unilateral facetectomy, although extraforaminal entry allows the facet to be spared. PURPOSE: To characterize the biomechanics of L4-L5 lumbar motion segments instrumented with bilateral transfacet pedicle screw (TFPS) fixation versus bilateral pedicle screw-rod (PSR) fixation in the setting of intact facets and native disc or after discectomy and extraforaminal placement of a TLIF technology graft. STUDY DESIGN: Human cadaveric lumbar spine segments were biomechanically tested in vitro to provide a nonpaired comparison of four configurations of posterior and interbody instrumentation. METHODS: Fourteen human cadaveric spine specimens (T12-S1) underwent standard pure moment flexibility tests with intact L4-L5 disc and facets. Seven were studied with intact discs, after TFPS fixation, and then with TLIF and TFPS fixation. The others were studied with intact discs, after PSR fixation, and then combined with extraforaminally placed TLIF. Loads were applied about anatomic axes to induce flexion-extension, lateral bending, and axial rotation. Three-dimensional specimen motion in response to applied loads during flexibility tests was determined. A nonpaired comparison of the four configurations of posterior and interbody instrumentation was made. RESULTS: Transfacet pedicle screw and PSR, with or without TLIF, significantly reduced range of motion during all directions of loading. Transfacet pedicle screw provided greater stability than PSR in all directions of motion except lateral bending. In flexion, TFPS was more stable than PSR (p=.042). A TLIF device provided less stability than the intact disc in constructs with TFPS and PSR. CONCLUSIONS: These results suggest that fixation at L4-L5 with TFPS is a promising alternative to PSR, with or without TLIF. A TLIF device was less stable than the native disc with both methods of instrumentation presumably because of a fulcrum effect from a relatively small footplate. Additional interbody support may be considered for improved biomechanics with TLIF. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1077 / 1082
页数:6
相关论文
共 19 条
[1]
Minimally invasive operative management for lumbar spinal stenosis: Overview of early and long-term outcomes [J].
Asgarzadie, Farbod ;
Khoo, Larry T. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2007, 38 (03) :387-+
[2]
Chin KR, 2013, J SPINAL DISORD TECH
[3]
A new technique for determining 3-D joint angles: the tilt/twist method [J].
Crawford, NR ;
Yamaguchi, GT ;
Dickman, CA .
CLINICAL BIOMECHANICS, 1999, 14 (03) :153-165
[4]
AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[5]
Construction of local vertebral coordinate systems using a digitizing probe - Technical note [J].
Crawford, NR ;
Dickman, CA .
SPINE, 1997, 22 (05) :559-563
[6]
Crawford NR, 1998, J SPINAL DISORD, V11, P416
[7]
A biomechanical comparison of facet screw fixation and pedicle screw fixation - Effects of short-term and long-term repetitive cycling [J].
Ferrara, LA ;
Secor, JL ;
Jin, BH ;
Wakefield, A ;
Inceoglu, S ;
Benzel, EC .
SPINE, 2003, 28 (12) :1226-1234
[8]
Transforaminal lumbar interbody fusion - The effect of various instrumentation techniques on the flexibility of the lumbar spine [J].
Harris, BM ;
Hilibrand, AS ;
Savas, PE ;
Pellegrino, A ;
Vaccaro, AR ;
Siegler, S ;
Albert, TJ .
SPINE, 2004, 29 (04) :E65-E70
[9]
Biomechanics of C-7 transfacet screw fixation Laboratory investigation [J].
Horn, Eric M. ;
Reyes, Phillip M. ;
Baek, Seungwon ;
Senoglu, Mehmet ;
Theodore, Nicholas ;
Sonntag, Volker K. H. ;
Crawford, Neil R. .
JOURNAL OF NEUROSURGERY-SPINE, 2009, 11 (03) :338-343
[10]
Biomechanics of a Lumbar Interspinous Anchor with Transforaminal Lumbar Interbody Fixation [J].
Kaibara, Taro ;
Karahalios, Dean G. ;
Porter, Randall W. ;
Kakarla, Udaya K. ;
Reyes, Phillip M. ;
Choi, Seok Kwang ;
Yaqoobi, Ali S. ;
Crawford, Neil R. .
WORLD NEUROSURGERY, 2010, 73 (05) :572-577