Sol-gel-derived prussian blue-silicate amperometric glucose biosensor

被引:22
作者
Bharathi, S [1 ]
Lev, O [1 ]
机构
[1] Hebrew Univ Jerusalem, Fredy & Nadine Hermann Sch Appl Sci, IL-91904 Jerusalem, Israel
关键词
sol-gel; biosensor; Prussian blue; modified electrodes;
D O I
10.1385/ABAB:89:2-3:209
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new type of inorganic biosensor is introduced. The sensor comprises glucose oxidase enzymes encapsulated in a sol-gel-derived Prussian blue-silicate hybrid network. Glucose is detected by the biocatalytic reduction of oxygen followed by catalytic reduction of hydrogen peroxide by the Prussian blue catalyst. The sol-gel silicate entails a rigid encapsulating matrix, the Prussian blue provides chemical catalysis and charge mediation from the reduction site to the supporting electrode, and the enzyme is responsible for the biocatalysis. The feasibility of a dual optical/electrochemical mode of analysis is also demonstrated.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 21 条
[11]   Prussian-Blue-based amperometric biosensors in flow-injection analysis [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
TALANTA, 1996, 43 (09) :1597-1606
[12]   PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2419-2423
[13]   Composite films of Prussian blue and N-substituted polypyrroles: covalent immobilization of enzymes and application to near infrared optical biosensing [J].
Koncki, R ;
Wolfbeis, OS .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) :87-92
[14]   Sol-gel materials in electrochemistry [J].
Lev, O ;
Wu, Z ;
Bharathi, S ;
Glezer, V ;
Modestov, A ;
Gun, J ;
Rabinovich, L ;
Sampath, S .
CHEMISTRY OF MATERIALS, 1997, 9 (11) :2354-2375
[15]  
Lu W, 1998, ELECTROANAL, V10, P472, DOI 10.1002/(SICI)1521-4109(199806)10:7<472::AID-ELAN472>3.3.CO
[16]  
2-2
[17]   Sol-gel-based amperometric glucose biosensor incorporating an osmium redox polymer as mediator [J].
Park, TM ;
Iwuoha, EI ;
Smyth, MR ;
MacCraith, BD .
ANALYTICAL COMMUNICATIONS, 1996, 33 (08) :271-273
[18]   EVALUATION OF AMPEROMETRIC GLUCOSE BIOSENSORS BASED ON COIMMOBILIZATION OF GLUCOSE-OXIDASE WITH AN OSMIUM REDOX POLYMER IN ELECTROCHEMICALLY GENERATED POLYPHENOL FILMS [J].
PRAVDA, M ;
JUNGAR, CM ;
IWUOHA, EI ;
SMYTH, MR ;
VYTRAS, K ;
IVASKA, A .
ANALYTICA CHIMICA ACTA, 1995, 304 (02) :127-138
[19]   Renewable, reagentless glucose sensor based on a redox modified enzyme and carbon-silica composite [J].
Sampath, S ;
Lev, O .
ELECTROANALYSIS, 1996, 8 (12) :1112-1116
[20]  
Walcarius A, 1998, ELECTROANAL, V10, P1217, DOI 10.1002/(SICI)1521-4109(199812)10:18<1217::AID-ELAN1217>3.3.CO