Tandem mass spectrometric accurate mass performance of time-of-flight and Fourier transform ion cyclotron resonance mass spectrometry: a case study with pyridine derivatives

被引:32
作者
Hau, J
Stadler, R
Jenny, TA
Fay, LB
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
[2] Univ Fribourg, Dept Chim, CH-1700 Fribourg, Switzerland
关键词
D O I
10.1002/rcm.444
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The interpretation of mass spectra is a key process during compound identification, and the combination of tandem mass spectrometry (MS/MS) with high-accuracy mass measurements may deliver crucial information on the identity of a compound. Obtaining accurate mass data of fragment ions in MS/MS reveals the particular problem of mass calibration when a lockmass, which is frequently used to obtain accurate masses in MS, is absent. An alternative technique is to recalibrate the MS/MS spectrum using a reference MS/MS spectrum acquired under the same conditions. We have tested and validated this approach using a hybrid quadrupole/orthogonal acceleration reflectron-type time-of-flight (TOF) mass spectrometer. The results were compared with those obtained under similar conditions on a Fourier transform ion cyclotron resonance (FT-ICR) instrument. We found that the mass accuracy observed with such an 'external' recalibration on the TOF instrument in MS/MS is identical to what can be obtained on a similar instrument operating in one-dimensional MS mode using the lockmass technique. However, mass accuracy in both cases is one order of magnitude inferior to that obtained using FTMS, and also inferior to that observed using sector field MS when operated at comparable resolution. Nevertheless, for small (< 200 Da) molecules, this mass accuracy was still sufficient to have the 'true' elemental composition identified as the first hit in about 70% of all cases. It was possible to elucidate the fragmentation mechanism of eight azaheterocycles containing a pyridine moiety, where the accurate mass data from the TOF instrument allowed distinction between two alternative fragmentation pathways. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1840 / 1848
页数:9
相关论文
共 22 条
[1]  
BRUNNEE C, 1987, INT J MASS SPECTROM, V76, P125, DOI 10.1016/0168-1176(87)80030-7
[2]   Analysis of water-soluble vitamins by high-performance liquid chromatography particle beam mass spectrometry [J].
Careri, M ;
Cilloni, R ;
Lugari, MT ;
Manini, P .
ANALYTICAL COMMUNICATIONS, 1996, 33 (05) :159-162
[3]   ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS [J].
CODY, RB ;
TAMURA, J ;
MUSSELMAN, BD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1561-1570
[4]   Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept [J].
Eckers, C ;
Wolff, JC ;
Haskins, NJ ;
Sage, AB ;
Giles, K ;
Bateman, R .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3683-3688
[5]   Study of the fragmentation of 3(2H)-furanones by mass spectrometry [J].
Fay, LB ;
HuynhBa, T ;
Blank, I .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (10) :4057-4064
[6]   High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry [J].
Flora, JW ;
Hannis, JC ;
Muddiman, DC .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1247-1251
[7]   Advantages of pressurization in capillary electrophoresis/electrospray ionization mass spectrometry [J].
Hau, J ;
Roberts, M .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :3977-3984
[8]   Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometer [J].
Hopfgartner, G ;
Chernushevich, IV ;
Covey, T ;
Plomley, JB ;
Bonner, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1305-1314
[9]   The impact of accurate mass measurements using quadrupole/time-of-flight mass spectrometry on the characterisation and screening of drug metabolites [J].
Hopfgartner, G ;
Vilbois, F .
ANALUSIS, 2000, 28 (10) :906-914A
[10]  
IIDA J, 1990, ANAL SCI, V6, P272