Preliminary study of the detectability of coronary plaque with PET

被引:13
作者
Delso, G. [1 ]
Martinez-Moeller, A. [1 ]
Bundschuh, R. A. [1 ]
Nekolla, S. G. [1 ]
Ziegler, S. I. [1 ]
Schwaiger, M. [1 ]
机构
[1] Tech Univ Munich, Nukl Med Klin & Poliklin, Klinikum Rechts Isar, D-81675 Munich, Germany
关键词
POSITRON-EMISSION-TOMOGRAPHY; RESPIRATORY MOTION-CORRECTION; ATHEROSCLEROTIC PLAQUES; SIMULATION TOOLKIT; CT; RECONSTRUCTION; INFLAMMATION; HEART; IMAGE; MODE;
D O I
10.1088/0031-9155/56/7/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The evaluation of coronary plaque vulnerability could be of great diagnostic value in cardiology. Positron emission tomography (PET) is a good candidate due to its ability to quantify micromolar concentrations of targeted drugs. However, the detectability of sub-voxel targets such as coronary plaque is limited by partial volume effects and by cardiorespiratory motion. The goal of this paper is to investigate the impact of these factors in the detectability of plaque uptake. Radioactive markers were implanted on the epicardium of a pig and in vivo scans were performed. This was complemented with phantom measurements to determine the minimum detectable uptake as a function of background activity. Simulations were used to evaluate the effect of cardiorespiratory motion on the reconstructed lesions. Despite cardiorespiratory motion of up to 7 mm, the markers were detectable in the in vivo scans even after the injection of background. A lower limit of 250 Bq was found for a target to be detectable. Motion reduced the contrast of the reconstructed lesions to 23% of their static counterpart. Respiratory gating improved this to 49% of the static value. The results suggest that coronary plaque evaluation with PET is possible, provided that sufficient plaque-to-myocardium uptake contrast (50 to 100) can be achieved. This requirement increases exponentially for lesions with uptake below 250 Bq. The described experiments provide a means of estimating the minimum uptake and contrast required to ensure the detectability of plaque lesions.
引用
收藏
页码:2145 / 2160
页数:16
相关论文
共 46 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Radioactive spheres without inactive wall for lesion simulation in PET [J].
Bazanez-Borgert, Marisa ;
Bundschuh, Ralph A. ;
Herz, Michael ;
Martinez, Maria-Jose ;
Schwalger, Markus ;
Ziegler, Sibylle I. .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (01) :37-42
[3]  
Ben-Haim S, 2006, Q J NUCL MED MOL IM, V50, P53
[4]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[5]   Joint Reconstruction of Image and Motion in Gated Positron Emission Tomography [J].
Blume, Moritz ;
Martinez-Moeller, Axel ;
Keil, Andreas ;
Navab, Nassir ;
Rafecas, Magdalena .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) :1892-1906
[6]  
Boucher L, 2004, J NUCL MED, V45, P214
[7]   FDG-PET is an effective imaging modality to detect and quantify age-related atherosclerosis in large arteries [J].
Bural, Gonca G. ;
Torigian, Drew A. ;
Chamroonrat, Wichana ;
Houseni, Mohamed ;
Chen, Wengen ;
Basu, Sandip ;
Kumar, Rakesh ;
Alavi, Abass .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (03) :562-569
[8]   Relationship between motion of coronary arteries and diaphragm during free breathing: Lessons from real-time MR imaging [J].
Danias, PG ;
Stuber, M ;
Botnar, RM ;
Kissinger, KV ;
Edelman, RR ;
Manning, WJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1061-1065
[9]   Respiratory motion correction in 3-D PET data with advanced optical flow algorithms [J].
Dawood, Mohammad ;
Buether, Florian ;
Jiang, Xiaoyi ;
Schaefers, Klaus P. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (08) :1164-1175
[10]  
Dunphy MPS, 2005, J NUCL MED, V46, P1278