How accurate are pulse oximeters in patients with acute exacerbations of chronic obstructive airways disease?

被引:50
作者
Kelly, AM [1 ]
McAlpine, R [1 ]
Kyle, E [1 ]
机构
[1] Western Hosp, Dept Emergency Med, Footscray, Vic 3011, Australia
关键词
pulse oximeter; oxygen saturation; chronic airways disease;
D O I
10.1053/rmed.2001.1046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine the extent of correlation and agreement between arterial oxygen saturation and oxygen saturation as recorded by transcutaneous pulse oximetry. with a view to identifying whether pulse oximetry can be used as an alternative to arterial values in the clinical management of patients with acute exacerbations of chronic obstructive airways disease (COAD) in the emergency department. It also aims to determine whether there is a cut-off level of oxygen saturation by pulse oximetry that can screen for significant systemic hypoxia in this group. This prospective study of patients with acute exacerbations of GOAD who Evert: deemed by their treating doctor to require an arterial blood gas analysis to determine their ventilatory status; compared arterial oxygen saturation with simultaneously recorded oxygen saturation measured by transcutaneous pulse oximetry. Data were analysed using Pearson correlation. bias plot (Bland-Altman) methods for agreement and the receiver operator characteristic (ROC) curve method for determination of a screening cut-off. Sixty-four sample-pairs were analysed for this study. Nine (14%) had significant hypoxia (arterial PO2 less than 60 mmHg). The correlation coefficient was 0(.)91. The bias (Bland-Altman) plot shows a constant bias of -0(.)758% and only fair agreement, with 95% limits for agreement of -8(.)2 to +6(.)7%. With respect to the ROC curve analysis, the 'best' cut-off for detection of hypoxia was at oxygen saturation by pulse oximetry of 92% (sensitivity 100%. specificity 86%). In conclusion, there is not sufficient agreement for oxygen saturation measured by pulse oximetry to replace analysis of on arterial blood gas sample in the clinical evaluation of oxygenation in emergency patients with GOAD. However. oxygen saturation by pulse oximetry may be an effective screening test for systemic hypoxia, with the screening cut-off of 92% having sensitivity for the detection of systemic hypoxia of 100% with specificity of 86%.
引用
收藏
页码:336 / 340
页数:5
相关论文
共 20 条
[1]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BOURCHIER D, 1984, AUST PAEDIATR J, V20, P213
[4]   ARTERIAL BLOOD-GAS ANALYSIS OR OXYGEN-SATURATION IN THE ASSESSMENT OF ACUTE ASTHMA [J].
CARRUTHERS, DM ;
HARRISON, BDW .
THORAX, 1995, 50 (02) :186-188
[5]  
CHAUDHARY BA, 1978, AM REV RESPIR DIS, V117, P173
[6]   RELIABILITY OF PULSE OXIMETRY DURING EXERCISE IN PULMONARY PATIENTS [J].
ESCOURROU, PJL ;
DELAPERCHE, MF ;
VISSEAUX, A .
CHEST, 1990, 97 (03) :635-638
[7]   CONTINUOUS INVIVO MONITORING OF ARTERIAL OXYGENATION IN CHRONIC OBSTRUCTIVE LUNG-DISEASE [J].
FLICK, MR ;
BLOCK, AJ .
ANNALS OF INTERNAL MEDICINE, 1977, 86 (06) :725-730
[8]  
FLICK MR, 1977, HEART LUNG, V6, P990
[9]  
JASTREMSKI M, 1993, CRIT CARE MED, V21, P615
[10]   Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults [J].
Jensen, LA ;
Onyskiw, JE ;
Prasad, NGN .
HEART & LUNG, 1998, 27 (06) :387-408