Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g-1 levels

被引:64
作者
Boulyga, SF [1 ]
Tibi, M [1 ]
Heumann, KG [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Inst Inorgan Chem & Analyt Chem, D-55099 Mainz, Germany
关键词
plutonium; soil; isotope dilution; laser ablation; inductively coupled plasma mass spectrometry;
D O I
10.1007/s00216-003-2193-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few mug g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of U-238(+) ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of Pu239+240 (9.8+/-3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4+/-0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if 'hot' particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.
引用
收藏
页码:342 / 347
页数:6
相关论文
共 24 条
[1]   Radioecological impacts of the Techa River contamination [J].
Akleyev, AV ;
Kostyuchenko, VA ;
Peremyslova, LM ;
Baturin, VA ;
Popova, IY .
HEALTH PHYSICS, 2000, 79 (01) :36-47
[2]  
[Anonymous], 1988, INORGANIC MASS SPECT
[3]  
[Anonymous], ENCY ANAL CHEM
[4]   Laser ablation inductively coupled plasma mass spectrometry for the trace, ultratrace and isotope analysis of long-lived radionuclides in solid samples [J].
Becker, JS ;
Pickhardt, C ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 202 (1-3) :283-297
[5]   Depth profiling of Pu, 241Am and 137Cs in soils from southern Belarus measured by ICP-MS and α and γ spectrometry [J].
Boulyga, SF ;
Zoriy, M ;
Ketterer, ME ;
Becker, JS .
JOURNAL OF ENVIRONMENTAL MONITORING, 2003, 5 (04) :661-666
[6]   Plutonium and americium determination in mosses by laser ablation ICP-MS combined with isotope dilution technique [J].
Boulyga, SF ;
Desideri, D ;
Meli, MA ;
Testa, C ;
Becker, JS .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 226 (03) :329-339
[7]   Determination of 236U/238U isotope ratio in contaminated environmental samples using different ICP-MS instruments [J].
Boulyga, SF ;
Matusevich, JL ;
Mironov, VP ;
Kudrjashov, VP ;
Halicz, L ;
Segal, I ;
McLean, JA ;
Montaser, A ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :958-964
[8]   Experimental study of radioactive aerosols in the vicinity of the Chernobyl Nuclear Power Plant [J].
Boulyga, SF ;
Lomonosova, EM ;
Zhuk, IV ;
Yaroshevich, OI ;
Kudrjashov, VP ;
Mironov, VP .
RADIATION MEASUREMENTS, 1999, 30 (06) :703-707
[9]   Plutonium in the Savannah River Site environment [J].
Carlton, WH ;
Murphy, CE ;
Evans, AG .
HEALTH PHYSICS, 1996, 71 (03) :290-299
[10]   ISOTOPIC AND NUCLEAR ANALYTICAL TECHNIQUES IN BIOLOGICAL-SYSTEMS - A CRITICAL-STUDY .10. ELEMENTAL ISOTOPE-DILUTION ANALYSIS WITH RADIOACTIVE AND STABLE ISOTOPES [J].
FASSETT, JD .
PURE AND APPLIED CHEMISTRY, 1995, 67 (11) :1943-1949