Assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodes

被引:59
作者
Heng, LY [1 ]
Hall, EAH [1 ]
机构
[1] Univ Cambridge, Inst Biotechnol, Cambridge CB2 1QT, England
关键词
cross-linked poly(n-butyl acrylate); solid-state ion sensor; photocure; ion-selective membrane; plasticiser; blood serum electrolyte;
D O I
10.1016/S0003-2670(01)01195-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A technique for the fabrication of solid-state ion sensors based on self-plasticising poly(n-butyl acrylate) matrix by photocuring described. The poly(n-butyl acrylate) membrane was prepared by photocuring a mixture of the monomer n-butyl acrylate, cross-linker, 2-hexanedioldiacrylate and photoinitiator, 2,2-dimethoxy-2-phenylacetophenone under UV irradiation. The optimum composition of the membranes is discussed. The photocured films produced were elastic, tough and exhibited excellent adhesion on Ag/AgCl substrates. In the optimum recipe no inherent anionic site response was observed for the blank membrane, but AIBN produced anionic site impurities if used as initiator. By incorporating ionophores and lipophilic anions during photopolymerisation, ion-selective membranes could be formed in situ on Ag/AgCl substrates. Immobilisation of ionophore was also possible if a photopolymer is able ionophore such as 4-acryloylamidobenzo-15-crown-5 was included during the photocuring process. Solid-state potassium ion sensors (based on valinomycin or immobilised 4-acryloylamidobenzo- 15-crown-5) and sodium ion sensor (based on bis[(12-crown-4)methyl]dodecylmethylmalonate) were fabricated using this technique. The potentiometric responses of all these solid-state ion sensors were comparable to the corresponding conventional plasticised poly(vinyl chloride) (PVC)-based ion-selective electrodes. The influence of the composition on the lower detection limit was discussed and preliminary studies of these sensors with artificial serum electrolytes indicated that the coextration of counter and interfering ions (rather than analyte buffering effects) predominated, raising the lower detection limit. Long term exposure in a complex media, e.g. real human blood serum resulted in a potential shift indicative of ion transport with full recovery of the sensor after 12 h. The overall manual fabrication reproducibility of the technique was satisfactory with sensors produced from the same batch demonstrated <5% variation in potentiometric performance. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 40
页数:16
相关论文
共 57 条
[21]   Evaluation of perchlorate tolerant photo-cured calcium selective electrodes for use in flow injection potentiometry [J].
DiBenedetto, LT ;
Dimitrakopoulos, T ;
Farrell, JR ;
Iles, PJ .
TALANTA, 1997, 44 (03) :349-356
[22]   A photo-cured calcium ion-selective electrode for use in flow injection potentiometry that tolerates high perchlorate levels [J].
Dimitrakopoulos, T ;
Farrell, JR ;
Iles, PJ .
ELECTROANALYSIS, 1996, 8 (04) :391-395
[23]  
DUMSCHAT C, 1989, ANAL CHIM ACTA, V219, P179
[24]   SELECTIVITY-MODIFYING INFLUENCE OF ANIONIC SITES IN NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES [J].
EUGSTER, R ;
GEHRIG, PM ;
MORF, WE ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2285-2289
[25]   Photocured polymers in ion-selective electrode membranes .6. Photopolymerized lithium sensitive ion-selective electrodes for flow injection potentiometry [J].
Farrell, JR ;
Iles, PJ ;
Dimitrakopoulos, T .
ANALYTICA CHIMICA ACTA, 1996, 335 (1-2) :111-116
[26]   Photocured polymers in ion-selective electrode membranes .5. Photopolymerised sodium sensitive ion-selective electrodes for flow injection potentiometry [J].
Farrell, JR ;
Iles, PJ ;
Dimitrakopoulos, T .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :133-137
[27]   CHEMICAL SENSORS, BIOSENSORS AND THICK-FILM TECHNOLOGY [J].
GALANVIDAL, CA ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (05) :225-231
[28]   Producing "self-plasticizing" ion-selective membranes [J].
Heng, LY ;
Hall, EAH .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :42-51
[29]   New solvent system for the improved electrochemical performance of screen-printed polyurethane membrane-based solid-state sensors [J].
Hower, RW ;
Shin, JH ;
Cha, GS ;
Meruva, RK ;
Meyerhoff, ME ;
Brown, RB .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :168-172
[30]   PLASTICIZED POLYVINYL-CHLORIDE) PROPERTIES AND CHARACTERISTICS OF VALINOMYCIN ELECTRODES - CURRENT TIME RESPONSES TO VOLTAGE STEPS [J].
IGLEHART, ML ;
BUCK, RP ;
HORVAI, G ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1988, 60 (10) :1018-1022