High-resolution capillary isoelectric focusing-electrospray ionization mass spectrometry for hemoglobin variants analysis

被引:54
作者
Tang, Q
Harrata, AK
Lee, CS
机构
[1] IOWA STATE UNIV SCI & TECHNOL,US DOE,DEPT CHEM,AMES,IA 50011
[2] IOWA STATE UNIV SCI & TECHNOL,US DOE,AMES LAB,AMES,IA 50011
关键词
D O I
10.1021/ac960169o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line capillary isoelectric focusing (CIEF)-electrospray ionization mass spectrometry (ESIMS) as a two-dimensional separation system is employed for high-resolution analysis of hemoglobin variants A, C, S, and F. The effects of moving ionic boundary inside the CIEF capillary and MS scan rate on the separation resolution and mass detection of hemoglobin variants are investigated. The formation of a moving ionic boundary due to the replacement of background electrolyte counterions with sheath liquid counterions can be minimized by combining cathodic mobilization with a gravity-induced hydrodynamic flow. Hemoglobin variants F and A, with a pf difference of 0.05 pH unit, are almost baseline resolved and identified in CIEF-ESIMS. The concentration detection limit for each hemoglobin variant is in the range of 10(-8) M, comparable to that obtained in two-dimensional gel electrophoresis using silver staining. initial preconcentration during the focusing step and the use of single-ion monitoring scan mode are responsible for improving detection limits.
引用
收藏
页码:2482 / 2487
页数:6
相关论文
共 9 条
[1]  
CREIGHTON TE, 1990, PROTEIN STRUCTURE PR, pCH3
[2]   LIQUID SHEATH EFFECTS ON THE SEPARATION OF PROTEINS IN CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY [J].
FORET, F ;
THOMPSON, TJ ;
VOUROS, P ;
KARGER, BL ;
GEBAUER, P ;
BOCEK, P .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4450-4458
[3]   ANALYSIS OF PROTEIN-FRACTIONS BY MICROPREPARATIVE CAPILLARY ISOELECTRIC-FOCUSING AND MATRIX-ASSISTED LASER-DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
FORET, F ;
MULLER, O ;
THORNE, J ;
GOTZINGER, W ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :157-166
[4]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[5]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[6]   FAST AND HIGH-RESOLUTION ANALYSIS OF HUMAN-SERUM TRANSFERRIN BY HIGH-PERFORMANCE ISOELECTRIC-FOCUSING IN CAPILLARIES [J].
KILAR, F ;
HJERTEN, S .
ELECTROPHORESIS, 1989, 10 (01) :23-29
[7]   OBSERVATION OF THE NONCOVALENT QUATERNARY ASSOCIATIONS OF PROTEINS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
LIGHTWAHL, KJ ;
SCHWARTZ, BL ;
SMITH, RD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (12) :5271-5278
[8]  
SHACKLETON CHL, 1994, MASS SPECTROMETRY CL, V2, pCH4
[9]   CAPILLARY ISOELECTRIC-FOCUSING ELECTROSPRAY MASS-SPECTROMETRY FOR PROTEIN-ANALYSIS [J].
TANG, Q ;
HARRATA, AK ;
LEE, CS .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3515-3519