Reproducibility of pediatric whole body bone and body composition measures by dual-energy X-ray absorptiometry using the GE lunar prodigy

被引:92
作者
Margulies, L
Horlick, M
Thornton, JC
Wang, J
Ioannidou, E
Heymsfield, SB
机构
[1] St Lukes Roosevelt Hosp, Body Composit Unit, New York, NY 10025 USA
[2] Columbia Univ, Childrens Hosp New York Presbyterian, New York, NY 10027 USA
关键词
dual-energy X-ray absorptiometry; pediatrics; precision; body composition; bone mineral density; bone mass;
D O I
10.1385/JCD:8:3:298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of dual-energy X-ray absorptiometry (DXA) in pediatrics is increasing. It is safe, readily available, and easily performed, but there is little information on reproducibility. The aim of this study is to evaluate the reproducibility of whole body DXA scans in children. Total and regional bone mineral density, bone mineral content, nonbone, lean fat mass, and percent fat were measured twice by whole body DXA (GE Lunar Prodigy) in 49 subjects (5 to 17 yr). Within each subject, between subjects, and reading standard deviations for each body component were evaluated as well as intraclass correlations (IQ and coefficients of variation (CV). Total body measurements had better IC and CV than regional results from the whole body scan, with legs and arms better than trunk and spine. IC values were >= 0.989 for total body, >= 0.976 for legs and arms, and >= 0.875 for trunk and spine. CV values ranged 0.18 to 1.97% for total body, and 0.96 to 6.91% for regional measures. These values confirm that body composition and bone mass by DXA are highly reproducible among pediatric subjects. The results of this study can be used by clinicians and researchers for interpretation of longitudinal observations and for power calculations.
引用
收藏
页码:298 / 304
页数:7
相关论文
共 24 条
[1]   Clinical applications of body composition measurements using DXA [J].
Albanese, CV ;
Diessel, E ;
Genant, HK .
JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (02) :75-85
[2]   Finsler Laplacians and minimal-energy maps [J].
Centore, P .
INTERNATIONAL JOURNAL OF MATHEMATICS, 2000, 11 (01) :1-13
[3]  
Ellis KJ, 1996, J BONE MINER RES, V11, P843
[4]   Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers [J].
Ellis, KJ ;
Shypailo, RJ .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) :1613-1618
[5]   Z score prediction model for assessment of bone mineral content in pediatric diseases [J].
Ellis, KJ ;
Shypailo, RJ ;
Hardin, DS ;
Perez, MD ;
Motil, KJ ;
Wong, WW ;
Abrams, SA .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (09) :1658-1664
[6]   ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR BODY-COMPOSITION MEASUREMENTS IN CHILDREN [J].
ELLIS, KJ ;
SHYPAILO, RJ ;
PRATT, JA ;
POND, WG .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (05) :660-665
[7]  
FASSLER ALC, 1995, PEDIATR CLIN N AM, V42, P811
[8]   Regional bone mass measurement from whole-body dual energy X-ray absorptiometry scan [J].
Hammami, M ;
Koo, KWM ;
Koo, WWK ;
Thomas, RT ;
Rakhman, D .
JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (02) :131-136
[9]   Prediction models for evaluation of total-body bone mass with dual-energy X-ray absorptiometry among children and adolescents [J].
Horlick, M ;
Wang, J ;
Pierson, RN ;
Thornton, JC .
PEDIATRICS, 2004, 114 (03) :E337-E345
[10]   Dual X-ray absorptiometry assessment of body composition in children with altered body posture [J].
Lark, RK ;
Henderson, RC ;
Renner, JB ;
Fung, EB ;
Stallings, VA ;
Conaway, M ;
Stevenson, RD .
JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (04) :325-335