Near-infrared fluorescence imaging of lymph nodes using a new enzyme sensing activatable macromolecular optical probe

被引:32
作者
Wunderbaldinger, P
Turetschek, K
Bremer, C
机构
[1] Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[2] Univ Munster, Dept Clin Radiol, Munster, Germany
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Ctr Mol Imaging Res, Boston, MA USA
关键词
lymphatic system; contrast media; experimental studies; optical imaging; near-infrared fluorescence imaging;
D O I
10.1007/s00330-003-1932-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to validate the use of near infrared fluorescence imaging (NIRF) using enzyme-sensitive optical probes for lymph node detection. An optical contrast probe that is activated by cystein proteases, such as cathepsin B, was used to visualize lymph nodes by NIRF reflectance imaging. In order to quantitate the uptake of the optical probe in lymphatic tissue, the biodistribution was assessed using the Indium-111 labeled optical probe. Sixteen Balb-c mice were injected either intravenously (i.v.) or subcutaneously (s.c.) with the NIRF-probe (2 mumol cyanine (Cy)/animal; i.v., n=10; s.c., n=6) and imaged 24 h after injection. Signal intensities and target-to-background ratios of various lymph nodes were measured by manual regions of interest (ROIs). Additional signal intensity measurements were performed of excised lymph nodes (n=21) from i.v. injected mice (24 h after injection) and compared with excised lymph nodes (n=8) of noninjected mice. The probe employed in this study was lymphotropic with approximately 3-4% accumulation in lymph nodes (3.4 +/- 0.8% ID/g). Measurements of the excised lymph nodes (after i.v. injection) confirmed a significant increase in lymph node fluorescence signal from baseline 26 +/- 7.6 arbitary units (AU) to 146 +/- 10.9 AU (p<0.0001). A significant increase in lymph node fluorescence signal was also seen in vivo throughout the body after i.v. injection (96 +/- 7.8 AU) and/or regionally after s.c. injection (141 +/- 11.5 AU) in comparison with baseline autofluorescence (26 7.6 AU). Target-to-background ratio was significantly higher after s.c. injection (6.6% +/- 0.81) compared with i.v. injection (4.8 +/- 0.67%). Detection and visualization of lymph nodes is feasible by NIRF imaging using a cystein-protease sensitive optical probe.
引用
收藏
页码:2206 / 2211
页数:6
相关论文
共 45 条
[1]   Novel receptor-targeted fluorescent contrast agents for in vivo tumor imaging [J].
Achilefu, S ;
Dorshow, RB ;
Bugaj, JE ;
Rajagopalan, R .
INVESTIGATIVE RADIOLOGY, 2000, 35 (08) :479-485
[2]   Lymphoscintigraphy, the sentinel node concept, and the intraoperative gamma probe in melanoma, breast cancer, and other potential cancers [J].
Alazraki, NP ;
Eshima, D ;
Eshima, LA ;
Herda, SC ;
Murray, DR ;
Vansant, JP ;
Taylor, AT .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (01) :55-67
[3]   PET imaging in oncology [J].
Bar-Shalom, R ;
Valdivia, AY ;
Blaufox, MD .
SEMINARS IN NUCLEAR MEDICINE, 2000, 30 (03) :150-185
[4]  
Becker A, 2000, ANN NY ACAD SCI, V921, P275
[5]   Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands [J].
Becker, A ;
Hessenius, C ;
Licha, K ;
Ebert, B ;
Sukowski, U ;
Semmler, W ;
Wiedenmann, B ;
Grötzinger, C .
NATURE BIOTECHNOLOGY, 2001, 19 (04) :327-331
[6]  
Becker A, 2000, PHOTOCHEM PHOTOBIOL, V72, P234, DOI 10.1562/0031-8655(2000)072<0234:MCAFOI>2.0.CO
[7]  
2
[8]   Lymph node metastases: Safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles - Initial clinical experience [J].
Bellin, MF ;
Roy, C ;
Kinkel, K ;
Thoumas, D ;
Zaim, S ;
Vanel, D ;
Tuchmann, C ;
Richard, F ;
Jacqmin, D ;
Delcourt, A ;
Challier, E ;
Lebret, T ;
Cluzel, P .
RADIOLOGY, 1998, 207 (03) :799-808
[9]   A long-circulating co-polymer in ''passive targeting'' to solid tumors [J].
Bogdanov, A ;
Wright, SC ;
Marecos, EM ;
Bogdanova, A ;
Martin, C ;
Petherick, P ;
Weissleder, R .
JOURNAL OF DRUG TARGETING, 1997, 4 (05) :321-&
[10]   LONG-CIRCULATING BLOOD-POOL IMAGING AGENTS [J].
BOGDANOV, A ;
WEISSLEDER, R ;
BRADY, TJ .
ADVANCED DRUG DELIVERY REVIEWS, 1995, 16 (2-3) :335-348