Surgical relief of causalgia with an artificial nerve guide tube: Successful surgical treatment of causalgia (Complex Regional Pain Syndrome Type II) by in situ tissue engineering with a polyglycolic acid-collagen tube

被引:50
作者
Inada, Y
Morimoto, S
Moroi, K
Endo, K
Nakamura, T
机构
[1] Kyoto Univ, Inst Frontier Med Sci, Dept Bioartificial Organs, Sakyo Ku, Kyoto 6068507, Japan
[2] Inada Hosp, Dept Orthopaed Surg, Nara, Japan
[3] Nara Rehabil Ctr, Dept Neurol, Nara, Japan
[4] Ooyodo Hosp, Dept Anesthesiol, Nara, Japan
[5] Kyoto Nerve Regenerat Res Ctr, Kyoto, Japan
关键词
causalgia; nerve guide tube; regeneration; Complex Regional Pain Syndrome Type II; in situ tissue engineering;
D O I
10.1016/j.pain.2005.05.033
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Two patients with causalgia associated with allodynia and finger contracture were treated surgically with a bioresorbable nerve guide tube made from polygycolic acid and collagen: the injured segment of the digital nerve was resected and the resulting gap (25 and 36 mm) was bridged with the tube. In both cases, a neuroma was found on the injured nerve and many sprouting branches were. After reconstruction, the causalgia and allodynia disappeared and movement of the fingers recovered during the following 6 months. Functional recovery was objectively identified for 1 year and 9 months. Both patients regained full use of their finger and were free of discomfort for up to 24 and 18 months, respectively. Since the first description of causalgia in 1864, there has been no definitive treatment for this intractable burning pain. Our experience shows that at least some types of causalgia can be resolved successfully by surgery. (c) 2005 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 30 条
[11]   Nerve regeneration across a 25-mm gap bridged by a polyglycolic acid collagen tube: A histological and electrophysiological evaluation of regenerated nerves [J].
Kiyotani, T ;
Teramachi, M ;
Takimoto, Y ;
Nakamura, T ;
Shimizu, Y ;
Endo, K .
BRAIN RESEARCH, 1996, 740 (1-2) :66-74
[12]  
Livingston WK., 1943, PAIN MECH PHYSL INTE
[13]   CLINICAL NERVE RECONSTRUCTION WITH A BIOABSORBABLE POLYGLYCOLIC ACID TUBE [J].
MACKINNON, SE ;
DELLON, AL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 85 (03) :419-424
[14]   Peripheral nerve regeneration across an 80-mm gap bridged by a polyglycolic acid (PGA)-collagen tube filled with laminin-coated collagen fibers: a histological and electrophysiological evaluation of regenerated nerves [J].
Matsumoto, K ;
Ohnishi, K ;
Kiyotani, T ;
Sekine, T ;
Ueda, H ;
Nakamura, T ;
Endo, K ;
Shimizu, Y .
BRAIN RESEARCH, 2000, 868 (02) :315-328
[15]  
MILLESI H, 1998, NERVE GRAGTS INDICAT
[16]  
Mitchell SW, 1864, GUNSHOT WOUNDS OTHER
[17]  
Moneim M., 1998, MANAGEMENT PERIPHERA
[18]   Artificial trachea and long term follow-up in carinal reconstruction in dogs [J].
Nakamura, T ;
Teramachi, M ;
Sekine, T ;
Kawanami, R ;
Fukuda, S ;
Yoshitani, M ;
Toba, T ;
Ueda, H ;
Hori, Y ;
Inoue, M ;
Shigeno, K ;
Taka, TN ;
Liu, Y ;
Tamura, N ;
Shimizu, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2000, 23 (10) :718-724
[19]  
Nakamura T., 2003, CONNECT TISSUE, V35, P53
[20]   Decade of pain control and research gets into gear in USA [J].
Nelson, R .