Establishing a new ultraviolet and near-infrared spectral responsivity scale

被引:19
作者
Fox, NP [1 ]
Theocharous, E [1 ]
Ward, TH [1 ]
机构
[1] Natl Phys Lab, Ctr Opt & Environm Metrol, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1088/0026-1394/35/4/56
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new primary spectral responsivity scale has been established in the ultraviolet (UV) and near-infrared (NIR) spectral regions (200 nm to 400 nm and 0.9 mu m to 2.5 mu m) at an uncertainty level of less than 0.5% (2 sigma) over most of this range. The new scale is maintained on solid-state transfer standard detectors which were calibrated traceable to the NPL cryogenic radiometer via spectrally flat pyroelectric detectors using monochromatic radiation from both laser and monochromator sources. The UV scale was established on GaAsP detectors while the NIR scale is based on InGaAs (0.9 mu m to 1.64 mu m) and modified InSb/sphere detectors (1 mu m to 2.5 mu m). This paper discusses the choice of the new transfer standard detectors, describes how the new scale was established, and analyses the component uncertainties which contribute to the total uncertainty associated with the new scale.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 11 条
[1]   INFRARED REFLECTION PROPERTIES OF 5 TYPES OF BLACK COATING FOR RADIOMETRIC DETECTORS [J].
BETTS, DB ;
CLARKE, FJJ ;
COX, LJ ;
LARKIN, JA .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (08) :689-696
[2]  
*BRIT STAND I, 1995, VOC METR
[3]   SPECTRAL REFERENCE DETECTOR FOR VISIBLE TO 12-MU-M REGION - CONVENIENT, SPECTRALLY FLAT [J].
DAY, GW ;
HAMILTON, CA ;
PYATT, KW .
APPLIED OPTICS, 1976, 15 (07) :1865-1868
[4]   Evaluation of solid-state detectors for ultraviolet radiometric applications [J].
Durant, NM ;
Fox, NP .
METROLOGIA, 1996, 32 (06) :505-508
[5]   Realization of a scale of absolute spectral response using the national institute of standards and technology high-accuracy cryogenic radiometer [J].
Gentile, TR ;
Houston, JM ;
Cromer, CL .
APPLIED OPTICS, 1996, 35 (22) :4392-4403
[6]   Spatial uniformity of responsivity for silicon, gallium nitride, germanium, and indium gallium arsenide photodiodes [J].
Larason, TC ;
Bruce, SS .
METROLOGIA, 1998, 35 (04) :491-496
[7]  
LIMPERIS T, 1989, INFRARED HDB, P40
[8]   IMPROVED SPECTRAL RESPONSIVITY SCALES AT THE NPL, 400-NM TO 20-MU-M [J].
NETTLETON, DH ;
PRIOR, TR ;
WARD, TH .
METROLOGIA, 1993, 30 (04) :425-432
[9]   THE HITRAN DATABASE - 1986 EDITION [J].
ROTHMAN, LS ;
GAMACHE, RR ;
GOLDMAN, A ;
BROWN, LR ;
TOTH, RA ;
PICKETT, HM ;
POYNTER, RL ;
FLAUD, JM ;
CAMYPEYRET, C ;
BARBE, A ;
HUSSON, N ;
RINSLAND, CP ;
SMITH, MAH .
APPLIED OPTICS, 1987, 26 (19) :4058-4097
[10]   PRESENT STATE OF THE COMPARISON BETWEEN RADIOMETRIC SCALES BASED ON 3 PRIMARY STANDARDS [J].
STOCK, M ;
FISCHER, J ;
FRIEDRICH, R ;
JUNG, HJ ;
THORNAGEL, R ;
ULM, G ;
WENDE, B .
METROLOGIA, 1993, 30 (04) :439-449