Simultaneous monitoring of temperature and T1:: Methods and preliminary results of application to drug delivery using thermosensitive liposomes

被引:28
作者
Bos, C [1 ]
Lepetit-Coiffé, M [1 ]
Quesson, B [1 ]
Moonen, CTW [1 ]
机构
[1] Univ Victor Segalen, CNRS, ERT, Lab Mol & Funct Imaging Physiol Therapy, F-33076 Bordeaux, France
关键词
local drug delivery; liposomes; MR thermometry; proton resonance frequency; R-1-measurement; Look-Locker;
D O I
10.1002/mrm.20635
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is presented to obtain temperature and longitudinal relaxivity measurements simultaneously and in near real-time. Quantitative relaxivity values are obtained from the signal magnitude from fast Look-Locker EPI data, whereas phase information from all signal samples on the recovery curve is combined to provide temperature values using the proton resonance frequency method. The utility of this technique is illustrated in an in vitro experiment with thermosensitive liposomes, which are studied as potential micro vehicles for local drug delivery. The method allowed measuring the evolution of relaxivity during RF-heating of liposomes containing a paramagnetic contrast agent, demonstrating increase of liposome permeability near the phase transition temperature. Potential applications are monitoring of local drug delivery using thermosensitive liposomes, and confirmation of reaching the liposomes' threshold temperature during thermal therapy.
引用
收藏
页码:1020 / 1024
页数:5
相关论文
共 21 条
[1]   Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation [J].
Botnar, RM ;
Steiner, P ;
Dubno, B ;
Erhart, P ;
von Schulthess, GK ;
Debatin, JF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :437-444
[2]   FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[3]   SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS [J].
CONTURO, TE ;
SMITH, GD .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :420-437
[4]  
de Zwart JA, 2001, MAGNET RESON MED, V45, P128, DOI 10.1002/1522-2594(200101)45:1<128::AID-MRM1017>3.0.CO
[5]  
2-M
[6]  
DEPOORTER J, 1995, MAGNET RESON MED, V33, P74, DOI 10.1002/mrm.1910330111
[7]  
DEZWART JA, 2000, P 8 M INT SOC MAGN R, P43
[8]   Thermosensitive paramagnetic liposomes for temperature control during MR imaging-guided hyperthermia: In vitro feasibility studies [J].
Fossheim, SL ;
Il'yasov, KA ;
Hennig, J ;
Bjornerud, A .
ACADEMIC RADIOLOGY, 2000, 7 (12) :1107-1115
[9]   ACCURATE MEASUREMENT OF T(1) IN-VIVO IN LESS-THAN 3 SECONDS USING ECHO-PLANAR IMAGING [J].
GOWLAND, P ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :351-354
[10]  
Huber PE, 2001, CANCER RES, V61, P8441