Ultra-light patient-controlled epidural analgesia during labor: effects of varying regimens on analgesia and physician workload

被引:22
作者
Carvalho, B [1 ]
Cohen, SE [1 ]
Giarrusso, K [1 ]
Durbin, M [1 ]
Riley, ET [1 ]
Lipman, S [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Anesthesia, Stanford, CA 94305 USA
关键词
patient-controlled epidural analgesia; labor; analgesia;
D O I
10.1016/j.ijoa.2005.02.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Patient-controlled epidural analgesia (PCEA) offers many advantages over continuous epidural infusions for maintenance of labor analgesia. Some of these benefits may depend on the PCEA settings. This study evaluated several regimens for "ultra-light" (0.125%) PCEA with basal continuous infusion (CI) in labor with goals of minimizing physician interventions while providing good analgesia. Methods: Two hundred and twenty ASA I-II women receiving epidural analgesia during active labor (cervical dilation < 5 cm) were randomly assigned in a double-blind manner to four treatment groups (n = 30 in each). Analgesia was maintained with a PCEA/CI pump using bupivacaine 0.0625% + sufentanil 0.35 mu g/mL. PCEA settings were: group A: CI 10 mL/h, PCEA bolus 6 mL, 8-min lockout; group B: CI 10 mL/h, PCEA bolus 12 mL, 16-min lockout; group C: Cl 15 mL/h, PCEA bolus 6 mL, 8-min lockout; group D: CI 15 mL/h, PCEA bolus 12 mL, 16-min lockout. Results: In groups A, B, C and D, 76, 77, 75 and 85% of parturients respectively, required no physician rescue boluses. Pain scores were low and maternal satisfaction was high in all groups, with minimal differences among them. Spontaneous vaginal delivery occurred in 78% of patients overall, instrumental (forceps or vacuum) delivery in 10% and cesarean section in 12%. Conclusions: These ultra-light PCEA regimens provided excellent analgesia with minimal physician workload and a high spontaneous delivery rate. Use of moderate to high-volume, ultra-light PCEA/CI techniques should facilitate provision of labor analgesia in busy obstetric units. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 18 条
[1]   Patient-controlled epidural analgesia during labor: The effects of the increase in bolus and lockout interval [J].
Bernard, JM ;
Le Roux, D ;
Vizquel, L ;
Barthe, A ;
Gonnet, JM ;
Aldebert, A ;
Benani, RM ;
Fossat, C ;
Frouin, J .
ANESTHESIA AND ANALGESIA, 2000, 90 (02) :328-332
[2]  
COHEN S, 2002, ANESTHESIOLOGY, V96, pP56
[3]   PCEA compared to continuous epidural infusion in an ultra-low-dose regimen for labor pain relief: a randomized study [J].
Eriksson, SL ;
Gentele, C ;
Olofsson, CH .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2003, 47 (09) :1085-1090
[4]   CONTINUOUS INFUSION EPIDURAL ANALGESIA IN OBSTETRICS - A COMPARISON OF 0.08-PERCENT AND 0.25-PERCENT BUPIVACAINE [J].
EWEN, A ;
MCLEOD, DD ;
MACLEOD, DM ;
CAMPBELL, A ;
TUNSTALL, ME .
ANAESTHESIA, 1986, 41 (02) :143-147
[5]  
FERRANTE FM, 1991, ANESTH ANALG, V73, P547
[6]  
FERRANTE FM, 1994, ANESTH ANALG, V79, P80
[7]   PATIENT-CONTROLLED EPIDURAL ANALGESIA IN LABOR - VARYING BOLUS DOSE AND LOCKOUT INTERVAL [J].
GAMBLING, DR ;
HUBER, CJ ;
BERKOWITZ, J ;
HOWELL, P ;
SWENERTON, JE ;
ROSS, PLE ;
CROCHETIERE, CT ;
PAVY, TJG .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03) :211-217
[8]  
GAMBLING DR, 1990, ANESTH ANALG, V70, P256
[9]   A COMPARATIVE-STUDY OF PATIENT CONTROLLED EPIDURAL ANALGESIA (PCEA) AND CONTINUOUS INFUSION EPIDURAL ANALGESIA (CIEA) DURING LABOR [J].
GAMBLING, DR ;
YU, P ;
COLE, C ;
MCMORLAND, GH ;
PALMER, L .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (03) :249-254
[10]   Obstetric anesthesia work force survey, 1981 versus 1992 [J].
Hawkins, JL ;
Gibbs, CP ;
Orleans, M ;
MartinSalvaj, G ;
Beaty, B .
ANESTHESIOLOGY, 1997, 87 (01) :135-143