Patient-controlled epidural analgesia during labor: The effects of the increase in bolus and lockout interval

被引:29
作者
Bernard, JM
Le Roux, D
Vizquel, L
Barthe, A
Gonnet, JM
Aldebert, A
Benani, RM
Fossat, C
Frouin, J
机构
[1] Polyclin Jean Villar, Dept Anesthesie Reanimat, F-33520 Bruges Bordeaux, France
[2] Polyclin Jean Villar, Clin Gynecol & Obstet, F-33520 Bruges Bordeaux, France
关键词
D O I
10.1097/00000539-200002000-00017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Most studies use a bolus size of <6 mL of 0.125% bupivacaine for patient-controlled epidural analgesia (PCEA) during labor. In this double-blinded, randomized study, we compared the efficacy of a larger bolus injected via a PCEA pump to a conventional PCEA setting. By using a combination of 0.125% bupivacaine with 1:800,000 epinephrine and 0.625 mu g/mL sufentanil, the first PCEA setting was typical (4 mL/8 min), whereas the other combined a 12-mL bolus dose and a 25-min lockout interval, i.e., similar maximal hourly dose. Rescue analgesia was provided with 6 mL of 0.25% bupivacaine. Patient satisfaction and pain were scored on verbal and visual analog scales. Data were analyzed from 103 parturients in the 12-mL/25-min group and 100 in the 4-mL/8-min group. In the 12-mL/25-min group, the median pain score on 0- to 10-cm visual analog scale was lower at 6-cm cervical dilation (1 [range = 0-8] vs 3 [0-8]) and at delivery (1 [0-10] vs 2 [0-101]). Satisfaction was also better (70% vs 38% "excellent" opinions, at 6-cm cervical dilation). Use of the pump (ratio of successful and total demands) was high and similar in both groups. Rescue analgesia was comparable. Doses of analgesics were greater in the 12-mL/ 25-min group (hourly bupivacaine dose = 13.9 +/- 5.3 [mean +/- SD] vs 9.4 +/- 4.1 mg). No differences were noted between groups for the severity of hypotension, ephedrine requirement, outcome of the delivery, and Apgar scores. Implications: A patient-controlled epidural analgesia setting that allows a parturient to receive an increased analgesic dose improves satisfaction with patient-controlled epidural analgesia during labor.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 19 条
[1]   Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour [J].
Capogna, G ;
Celleno, D ;
Lyons, G ;
Columb, M ;
Fusco, P .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) :11-13
[2]   Effects of diluent volume of a single dose of epidural bupivacaine in parturients during the first stage of labor [J].
Christiaens, F ;
Verborgh, C ;
Dierick, A ;
Camu, F .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 1998, 23 (02) :134-141
[3]  
FERRANTE FM, 1991, ANESTH ANALG, V73, P547
[4]  
FERRANTE FM, 1994, ANESTH ANALG, V79, P80
[5]   0.0625-PERCENT BUPIVACAINE WITH 0.0002-PERCENT FENTANYL VIA PATIENT-CONTROLLED EPIDURAL ANALGESIA FOR PAIN OF LABOR AND DELIVERY [J].
FERRANTE, FM ;
BARBER, MJ ;
SEGAL, M ;
HUGHES, NJ ;
DATTA, S .
CLINICAL JOURNAL OF PAIN, 1995, 11 (02) :121-126
[6]   PATIENT-CONTROLLED EPIDURAL ANALGESIA IN LABOR - VARYING BOLUS DOSE AND LOCKOUT INTERVAL [J].
GAMBLING, DR ;
HUBER, CJ ;
BERKOWITZ, J ;
HOWELL, P ;
SWENERTON, JE ;
ROSS, PLE ;
CROCHETIERE, CT ;
PAVY, TJG .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03) :211-217
[7]  
GAMBLING DR, 1990, ANESTH ANALG, V70, P256
[8]   Comparison of three solutions of ropivacaine/fentanyl for postoperative patient-controlled epidural analgesia [J].
Liu, SS ;
Moore, JM ;
Luo, AM ;
Trautman, WJ ;
Carpenter, RL .
ANESTHESIOLOGY, 1999, 90 (03) :727-733
[9]   PATIENT-CONTROLLED EPIDURAL ANALGESIA DURING LABOR - A COMPARISON OF 3 SOLUTIONS WITH A CONTINUOUS INFUSION CONTROL [J].
LYSAK, SZ ;
EISENACH, JC ;
DOBSON, CE .
ANESTHESIOLOGY, 1990, 72 (01) :44-49
[10]  
Milligan K R, 1993, Int J Obstet Anesth, V2, P134, DOI 10.1016/0959-289X(93)90005-3