Pulse-train stimulation for detecting medial malpositioning of thoracic pedicle screws

被引:27
作者
Donohue, Miriam L. [1 ]
Murtagh-Schaffer, Catherine [2 ]
Basta, John [3 ]
Moquin, Ross R. [2 ]
Bashir, Asif [2 ]
Calancie, Blair [2 ]
机构
[1] Upstate Med Univ, Dept Cell & Dev Biol, Syracuse, NY USA
[2] Upstate Med Univ, Dept Neurosurg, Syracuse, NY USA
[3] Univ Hosp, Dept Neurosurg, Syracuse, NY USA
关键词
thoracic; bone screw; intraoperative monitoring; electrical stimulation; electromyographies; humans;
D O I
10.1097/BRS.0b013e31817343c1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Thoracic pedicle screw location and the current needed to stimulate adjacent neural tissue was evaluated using brief, high-frequency pulse trains and monitoring electromyography (EMG) from muscles in the lower limbs. Objective. To establish a safe and reliable method for detecting medial malpositioning of pedicle screws placed in the thoracic spine during instrumentation and fusion. Summary of Background Data. Neurophysiologic studies for testing thoracic pedicle screw placement used single-pulse stimulation and monitored EMG from thoracic-innervated muscles. We propose that with this approach, stimulation fails to activate lower motor neurons innervated by spinal cord axons, such that medial malplacement of screws will go largely undetected. Methods. EMG was monitored from multiple lower-limb muscles. Pedicle tracks were created free-hand, using a curved pedicle finder. A ball-tipped probe-insulated along its shaft-was used to palpate the walls of the pedicle tracks. During probing, constant-current, high-frequency 4-pulse stimulus trains were delivered through the ball tip, and the minimum current (i.e., threshold) needed to evoke EMG was determined for each pedicle track. The threshold current for stimulation through each screw was also determined. Postoperative serial computed tomography scans of all implanted thoracic and L1 screws were rated with respect to screw position and the pedicle wall. Results. A total of 116 screws were implanted in 7 subjects. Two pedicle tracks were redirected during surgery because of particularly low thresholds to stimulation. Definite medial defects were found in 19 screws, 18 of which were detected by the experimental technique. For these screws, the average threshold to probe stimulation of their associated pedicle tracks was 7.9 +/- 4.6 mA, much lower than current thresholds for less medially placed pedicle tracks. Stimulation of these screws resulted in high thresholds (19.8 +/- 5.3 mA) when a response was evoked at all; stimulating 8 of these 19 medially malpositioned screws failed to elicit any lower-limb EMG at considerably higher (25 or 30 mA) stimulus intensities. Conclusion. This preliminary study supports the hypothesis that high-frequency stimulus pulse trains are effective at detecting defects in the medial wall of pedicles in the thoracic spine during instrumentation, thereby improving on techniques using single-pulse stimulus protocols.
引用
收藏
页码:E378 / E385
页数:8
相关论文
共 55 条
[1]
Pedicle screws with high electrical resistance - A potential source of error with stimulus-evoked EMG [J].
Anderson, DG ;
Wierzbowski, LR ;
Schwartz, DM ;
Hilibrand, AS ;
Vaccaro, AR ;
Albert, TJ .
SPINE, 2002, 27 (14) :1577-1581
[2]
FUNCTIONAL ORGANIZATION OF A CORTICAL EFFERENT SYSTEM EXAMINED WITH FOCAL DEPTH STIMULATION IN CATS [J].
ASANUMA, H ;
SAKATA, H .
JOURNAL OF NEUROPHYSIOLOGY, 1967, 30 (01) :35-&
[3]
Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities [J].
Belmont, PJ ;
Klemme, WR ;
Robinson, M ;
Polly, DW .
SPINE, 2002, 27 (14) :1558-1566
[4]
In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[5]
Comparison of thoracic pedicle screw to hook instrumentation for the treatment of adult spinal deformity [J].
Bess, R. Shay ;
Lenke, Lawrence G. ;
Bridwell, Keith H. ;
Cheh, Gene ;
Mandel, Stephen ;
Sides, Brenda .
SPINE, 2007, 32 (05) :555-561
[6]
MORPHOMETRIC ANALYSIS OF EXPERIMENTAL SPINAL-CORD INJURY IN THE CAT - THE RELATION OF INJURY INTENSITY TO SURVIVAL OF MYELINATED AXONS [J].
BLIGHT, AR ;
DECRESCITO, V .
NEUROSCIENCE, 1986, 19 (01) :321-+
[7]
Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery [J].
Bose, B ;
Wierzbowski, LR ;
Sestokas, AK .
SPINE, 2002, 27 (13) :1444-1450
[8]
Threshold-level multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring [J].
Calancie, B ;
Harris, W ;
Broton, JG ;
Alexeeva, N ;
Green, BA .
JOURNAL OF NEUROSURGERY, 1998, 88 (03) :457-470
[9]
INTRAOPERATIVE EVOKED EMG MONITORING IN AN ANIMAL-MODEL - A NEW TECHNIQUE FOR EVALUATING PEDICLE SCREW PLACEMENT [J].
CALANCIE, B ;
LEBWOHL, N ;
MADSEN, P ;
KLOSE, KJ .
SPINE, 1992, 17 (10) :1229-1235
[10]
STIMULUS-EVOKED EMG MONITORING DURING TRANSPEDICULAR LUMBOSACRAL SPINE INSTRUMENTATION - INITIAL CLINICAL-RESULTS [J].
CALANCIE, B ;
MADSEN, P ;
LEBWOHL, N .
SPINE, 1994, 19 (24) :2780-2786