A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data

被引:205
作者
Kang, Y [1 ]
Engelke, K [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
accuracy; computed tomography; noise sensitivity; precision; 3-D bone segmentation;
D O I
10.1109/TMI.2003.812265
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We developed a highly automated three-dimensionally based method for the segmentation of bone in volumetric computed tomography (CT) datasets. The multistep approach starts with three-dimensional (3-D) region-growing using local adaptive thresholds followed by procedures to correct for remaining boundary discontinuities and a subsequent anatomically oriented boundary adjustment using local values of cortical bone density. We describe the details of our approach and show applications in the proximal femur, the knee, and the skull. The accuracy of the determination of geomtrical parameters was analyzed using CT scans of the semi-anthropoinorphic European spine phantom. Depending on the settings of the segmentation parameters cortical thickness could be determined with an accuracy corresponding to the side length of 1 to 2.5 voxels. The impact of noise on the segmentation was investigated by artificially adding noise to the CT data. An increase in noise by factors of two and five changed cortical thickness corresponding to the side length of one voxel. Intraoperator and interoperator precision was analyzed by repeated analysis of nine pelvic CT scans. Precision errors were smaller than 1% for trabecular and total volumes and smaller than 2% for cortical thickness. Intraoperator and interoperator precision errors were not significantly different. Our segmentation approach shows: 1) high accuracy and precision and is 2) robust to noise, 3) insensitive to user-defined thresholds, 4) highly automated and fast, and 5) easy to initialize.
引用
收藏
页码:586 / 598
页数:13
相关论文
共 22 条
[1]   SEEDED REGION GROWING [J].
ADAMS, R ;
BISCHOF, L .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1994, 16 (06) :641-647
[2]  
BANKMAN IN, 2000, HDB MED IMAGING, P185
[3]  
DURBIN J, 1950, BIOMETRIKA, V37, P409, DOI 10.1093/biomet/37.3-4.409
[4]  
Fuchs TOJ, 2001, PHYS MEDICA, V17, P129
[5]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[6]  
HEITZ M, 1995, THESIS U TUBINGEN TU
[7]  
HEITZ M, 1994, 10 INT BON DENS WORK
[8]   THE EUROPEAN SPINE PHANTOM - A TOOL FOR STANDARDIZATION AND QUALITY-CONTROL IN SPINAL BONE-MINERAL MEASUREMENTS BY DXA AND QCT [J].
KALENDER, WA ;
FELSENBERG, D ;
GENANT, HK ;
FISCHER, M ;
DEQUEKER, J ;
REEVE, J .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 20 (02) :83-92
[9]   VERTEBRAL BONE-MINERAL ANALYSIS - AN INTEGRATED APPROACH WITH CT [J].
KALENDER, WA ;
KLOTZ, E ;
SUESS, C .
RADIOLOGY, 1987, 164 (02) :419-423
[10]   Cartilage segmentation of 3D MRI scans of the osteoarthritic knee combining user knowledge and active contours. [J].
Lynch, JA ;
Zaim, S ;
Zhao, J ;
Stork, A ;
Peterfy, CG ;
Genant, HK .
MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 :925-935