Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging

被引:680
作者
Reeder, SB
Pineda, AR
Wen, ZF
Shimakawa, A
Yu, HZ
Brittain, JH
Gold, GE
Beaulieu, CH
Pelc, NJ
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
fat suppression; fast spin echo; magnetic resonance imaging; water-fat separation; asymmetric echoes; brachial plexus;
D O I
10.1002/mrm.20624
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to B. inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2 pi/3, with the middle echo centered at pi/2+pi k (k = any integer), i.e., (-pi/6+pi k, pi/2+pi k, 7 pi/6+pi k). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.
引用
收藏
页码:636 / 644
页数:9
相关论文
共 35 条
[1]
Chemical shift imaging with spectrum modeling [J].
An, L ;
Xiang, QS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :126-130
[2]
Consistent fat suppression with compensated spectral-spatial pulses [J].
Block, W ;
Pauly, J ;
Kerr, A ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :198-206
[3]
MR-IMAGING OF FAT-CONTAINING TISSUES - VALUATION OF 2 QUANTITATIVE IMAGING TECHNIQUES IN COMPARISON WITH LOCALIZED PROTON SPECTROSCOPY [J].
BRIX, G ;
HEILAND, S ;
BELLEMANN, ME ;
KOCH, T ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :977-991
[4]
BYDDER G M, 1985, Magnetic Resonance Imaging, V3, P251, DOI 10.1016/0730-725X(85)90354-6
[5]
SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[6]
ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[7]
MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530
[8]
3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[9]
SEPARATION OF FAT AND WATER IN FAST SPIN-ECHO MR-IMAGING WITH THE 3-POINT DIXON TECHNIQUE [J].
HARDY, PA ;
HINKS, RS ;
TKACH, JA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02) :181-185
[10]
Fat-suppressed steady-state free precession imaging using phase detection [J].
Hargreaves, BA ;
Vasanawala, SS ;
Nayak, KS ;
Hu, BS ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :210-213